Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 328

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reference Values for Normal Pulmonary Artery Dimensions by Noncontrast Cardiac Computed Tomography: The Framingham Heart Study

Open access
Truong, Quynh A., Massaro, Joseph M., Rogers, Ian S., Mahabadi, Amir A., Kriegel, Matthias F., Fox, Caroline S., O'Donnell, Christopher J., Hoffmann, Udo·2012·Circulation: Cardiovascular Imaging

Abstract

Background—: Main pulmonary artery diameter (mPA) and ratio of mPA to ascending aorta diameter (ratio PA) derived from chest CT are commonly reported in clinical practice. We determined the age- and sex-specific distribution and normal reference values for mPA and ratio PA by CT in an asymptomatic community-based population. Methods and Results—: In 3171 men and women (mean age, 51±10 years; 51% men) from the Framingham Heart Study, a noncontrast, ECG-gated, 8-slice cardiac multidetector CT was performed. We measured the mPA and transverse axial diameter of the ascending aorta at the level of the bifurcation of the right pulmonary artery and calculated the ratio PA. We defined the healthy referent cohort (n=706) as those without obesity, hypertension, current and past smokers, chronic obstructive pulmonary disease, history of pulmonary embolism, diabetics, cardiovascular disease, and heart valve surgery. The mean mPA diameter in the overall cohort was 25.1±2.8 mm and mean ratio PA was 0.77±0.09. The sex-specific 90th percentile cutoff value for mPA diameter was 28.9 mm in men and 26.9 mm in women and was associated with increase risk for self-reported dyspnea (adjusted odds ratio, 1.31; P =0.02). The 90th percentile cutoff value for ratio PA of the healthy referent group was 0.91, similar between sexes but decreased with increasing age (range, 0.82–0.94), though not associated with dyspnea. Conclusions—: For simplicity, we established 29 mm in men and 27 mm in women as sex-specific normative reference values for mPA and 0.9 for ratio PA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.111.968610

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 328

Metadata

Authors
Truong, Q. A., Massaro, J. M., Rogers, I. S., Mahabadi, A. A., Kriegel, M. F., Fox, C. S., O'Donnell, C. J., & Hoffmann, U.
Venue
Circulation: Cardiovascular Imaging
Published
2012-01
Volume
5
Issue
1
Pages
147-154
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W1999498547
Cited by
328
References
1
FWCI
5.44
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference Values for Normal Pulmonary Artery Dimensions by Noncontrast Cardiac Computed Tomography: The Framingham Heart Study. https://app.cochat.ai/papers/10.1161/circimaging.111.968610
The paper
Truong, Q. A., Massaro, J. M., Rogers, I. S., Mahabadi, A. A., Kriegel, M. F., Fox, C. S., O'Donnell, C. J., & Hoffmann, U. (2012). Reference Values for Normal Pulmonary Artery Dimensions by Noncontrast Cardiac Computed Tomography: The Framingham Heart Study. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.111.968610

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.