Diagnostic Accuracy of Cardiac Positron Emission Tomography Versus Single Photon Emission Computed Tomography for Coronary Artery Disease: A Bivariate Meta-Analysis

Parker, Matthew W., Iskandar, Aline, Limone, Brendan, Perugini, Andrew, Kim, Hyejin, Jones, Charles, Calamari, Brian, Coleman, Craig I., Heller, Gary V.·2012·Circulation: Cardiovascular Imaging

Abstract

Background—: Positron emission tomography (PET) myocardial perfusion imaging (MPI) offers technical benefits compared with single photon emission computed tomography (SPECT) MPI, but there has been no systematic comparison of their diagnostic accuracy for coronary artery disease. We performed a bivariate meta-analysis of the published literature to compare the sensitivity and specificity of PET versus SPECT stress MPI for ≥50% stenosis of any epicardial coronary artery in patients with known or suspected coronary artery disease. Methods and Results—: We searched MEDLINE and EMBASE from inception through January 2012 and the references of identified studies for prospective, English language studies that evaluated the sensitivity and specificity of PET and/or SPECT MPI with coronary angiography as the reference standard and reported sufficient data to calculate patient-level true and false positives and negatives. Two investigators independently extracted patient and study characteristics; a third investigator resolved any disagreements. We identified 117 studies, including 108 evaluating SPECT MPI, 4 evaluating PET MPI, and 5 evaluating both modalities. Bivariate meta-analysis demonstrated a significantly higher pooled mean sensitivity with PET (92.6% [95% Confidence Interval, 88.3% to 95.5%]) compared with SPECT (88.3% [95% confidence interval, 86.4% to 90.0%]) ( P =0.035). No significant difference in specificity was observed between PET (81.3% [95% confidence interval, 66.6% to 90.4%]) and SPECT (75.8% [95% confidence interval, 72.1% to 79.1%]) ( P =0.39). Few studies investigated coronary angiography with PET. Only 5 studies directly compared SPECT and PET. Conclusions—: In a meta-analysis of 11,862 patients, PET MPI demonstrated a higher sensitivity for coronary artery disease than SPECT MPI. No difference in specificity was detected in the pooled analysis of PET and SPECT MPI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.112.978270

Cites

64 of 64 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 64 references

Cited by

See all 257

Metadata

Authors
Parker, M. W., Iskandar, A., Limone, B., Perugini, A., Kim, H., Jones, C., Calamari, B., Coleman, C. I., & Heller, G. V.
Venue
Circulation: Cardiovascular Imaging
Published
2012-11
Volume
5
Issue
6
Pages
700-707
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2625644546
Cited by
257
References
64
FWCI
17.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic Accuracy of Cardiac Positron Emission Tomography Versus Single Photon Emission Computed Tomography for Coronary Artery Disease: A Bivariate Meta-Analysis. https://app.cochat.ai/papers/10.1161/circimaging.112.978270
The paper
Parker, M. W., Iskandar, A., Limone, B., Perugini, A., Kim, H., Jones, C., Calamari, B., Coleman, C. I., & Heller, G. V. (2012). Diagnostic Accuracy of Cardiac Positron Emission Tomography Versus Single Photon Emission Computed Tomography for Coronary Artery Disease: A Bivariate Meta-Analysis. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.112.978270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.