Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Age-, Body Size-, and Sex-Specific Reference Values for Right Ventricular Volumes and Ejection Fraction by Three-Dimensional Echocardiography: A Multicenter Echocardiographic Study in 507 Healthy Volunteers

Open access
Maffessanti, Francesco, Muraru, Denisa, Esposito, Roberta, Gripari, Paola, Ermacora, Davide, Santoro, Ciro, Tamborini, Gloria, Galderisi, Maurizio, Pepi, Mauro, Badano, Luigi P.·2013·Circulation: Cardiovascular Imaging

Abstract

Background—: Right ventricular (RV) volumes and ejection fraction (EF) vary significantly with demographic and anthropometric factors and are associated with poor prognosis in several cardiovascular diseases. This multicenter study was designed to (1) establish the reference values for RV volumes and EF using transthoracic three-dimensional (3D) echocardiography; (2) investigate the influence of age, sex, and body size on RV anatomy; (3) develop normative equations. Methods and Results—: RV volumes (end-diastolic volume and end-systolic volume), stroke volume, and EF were measured by 3D echocardiography in 540 healthy adult volunteers, prospectively enrolled, evenly distributed across age and sex. The relation of age, sex, and body size parameters was investigated using bivariate and multiple linear regression. Analysis was feasible in 507 (94%) subjects (260 women; age, 45±16 years; range, 18–90). Age, sex, height, and weight significantly influenced RV volumes and EF. Sex effect was significant ( P <0.01), with RV volumes larger and EF smaller in men than in women. Older age was associated with lower volumes (end-diastolic volume, −5 mLdecade; end-systolic volume, −3 mL/decade; EF, −2 mL/decade) and higher EF (+1% per decade). Inclusion of body size parameters in the statistical models resulted in improved overall explained variance for volumes (end-diastolic volume, R 2 =0.43; end-systolic volume, R 2 =0.35; stroke volume, R 2 =0.30), while EF was unaffected. Ratiometric and allometric indexing for age, sex, and body size resulted in no significant residual correlation between RV measures and height or weight. Conclusions—: The presented normative ranges and equations could help standardize the 3D echocardiography assessment of RV volumes and function in clinical practice, considering the effects of age, sex, and body size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.113.000706

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 235

Metadata

Authors
Maffessanti, F., Muraru, D., Esposito, R., Gripari, P., Ermacora, D., Santoro, C., Tamborini, G., Galderisi, M., Pepi, M., & Badano, L. P.
Venue
Circulation: Cardiovascular Imaging
Published
2013-09
Volume
6
Issue
5
Pages
700-710
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2128109219
Cited by
235
References
2
FWCI
10.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Age-, Body Size-, and Sex-Specific Reference Values for Right Ventricular Volumes and Ejection Fraction by Three-Dimensional Echocardiography: A Multicenter Echocardiographic Study in 507 Healthy Volunteers. https://app.cochat.ai/papers/10.1161/circimaging.113.000706
The paper
Maffessanti, F., Muraru, D., Esposito, R., Gripari, P., Ermacora, D., Santoro, C., Tamborini, G., Galderisi, M., Pepi, M., & Badano, L. P. (2013). Age-, Body Size-, and Sex-Specific Reference Values for Right Ventricular Volumes and Ejection Fraction by Three-Dimensional Echocardiography: A Multicenter Echocardiographic Study in 507 Healthy Volunteers. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.113.000706

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.