Cited by 168Advanced MRI Techniques and ApplicationsCongenital Heart Disease StudiesFetal and Pediatric Neurological Disorders

Reference Ranges of Blood Flow in the Major Vessels of the Normal Human Fetal Circulation at Term by Phase-Contrast Magnetic Resonance Imaging

Prsa, Milan, Sun, Liqun, van Amerom, Joshua, Yoo, Shi-Joon, Grosse-Wortmann, Lars, Jaeggi, Edgar, Macgowan, Christopher, Seed, Mike·2014·Circulation: Cardiovascular Imaging

Abstract

Background—: Phase-contrast MRI with metric-optimized gating is a promising new technique for studying the distribution of the fetal circulation. However, mean and reference ranges for blood flow measurements made in the major fetal vessels using this technique are yet to be established. Methods and Results—: We measured flow in the major vessels of the fetal circulation in 40 late-gestation normal human fetuses using phase-contrast MRI (mean gestational age, 37 [SD=1.1] weeks). Flows were indexed to the fetal weight, which was estimated from the fetal volume calculated by MRI segmentation. The following mean flows (in mL/min per kilogram; ±2SD) were obtained: combined ventricular output, 465 (351, 579); main pulmonary artery, 261 (169, 353); ascending aorta, 191 (121, 261); superior vena cava, 137 (77, 197); ductus arteriosus, 187 (109, 265); descending aorta, 252 (160, 344); pulmonary blood flow, 77 (0, 160); umbilical vein, 134 (62, 206); and foramen ovale, 135 (37, 233). Expressed as percentages of the combined ventricular output, the mean flows±2 SD were as follows: main pulmonary artery, 56 (44, 68); ascending aorta, 41 (29, 53); superior vena cava, 29 (15, 43); ductus arteriosus, 41 (25, 57); descending aorta, 55 (35, 75); pulmonary blood flow, 16 (0, 34); umbilical vein, 29 (11, 47); and foramen ovale, 29 (7, 51). A strong inverse relationship between foramen ovale shunt and pulmonary blood flow was noted ( r =−0.64; P <0.0001). Conclusions—: Although too small a sample size to provide normal ranges, these results are in keeping with those predicted in humans based on measurements made in fetal lambs using radioactive microspheres and provide preliminary reference ranges for the late-gestation human fetuses. The wide range we found in foramen ovale shunting suggests a degree of variability in the way blood is streamed through the fetal circulation.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.113.001859

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 41 · Cited by 168

Research works printed but not linked: 4

  1. Porayette P, van Amerom JFP, Yoo SJ, Macgowan CK, Seed M. MRI shows limited mixing between systemic and pulmonary circulations -a potential cause of in utero pulmonary vascular disease. Cardiol Young. In press.
  2. Van Amerom JFP, Roy CW, Prsa M, Kingdom, JC, Macgowan CK, Seed M. Assessment of late-onset fetal growth restriction by phase contrast MR. Abstract. Proc Intl Soc Mag Reson Med. 2013;21:4129.
  3. Yoo SJ, Lee YH, Cho KS, Kim DY. Sequential segmental analysis of fetal congenital heart disease. Cardiol Young. 1999;9:430-444.
  4. Sun L, Al-Rujaib M, van Amerom JFP, Macgowan CK, Seed M. Comprehensive assessment of late gestation human fetal circulation by phase contrast MRI and T2 mapping. Abstract. Proc Intl Soc Mag Reson Med. 2014;22:0857.

Authors
Prsa, M., Sun, L., van Amerom, J., Yoo, S.-J., Grosse-Wortmann, L., Jaeggi, E., Macgowan, C., & Seed, M.
Affiliations
  • From the Division of Pediatric Cardiology, Department of Pediatrics (M.P., L.S., L.G.-W., E.J., M.S.), Department of Diagnostic Imaging (J.v.A., S.-J.Y., M.S.), and Department of Physiology and Experimental Medicine (C.M.), University of Toronto and Hospital for Sick Children, Toronto, Canada.
  • University of Toronto (CA)
Venue
Circulation: Cardiovascular Imaging
Published
2014-07
Volume
7
Issue
4
Pages
663-670
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2547290215
Cited by
168
References
41
Citations by year
2026: 4 · 2025: 12 · 2024: 13 · 2023: 14 · 2022: 16 · 2021: 22 · 2020: 15 · 2019: 24 · 2018: 19 · 2017: 8 · 2016: 8 · 2015: 10 · 2014: 1
FWCI
7.01
Type
journal article
Language
en
Open access
closed
Locations
  • Circulation Cardiovascular Imaging (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS (submittedVersion)
  • Research Portal (King's College London) (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Fetal and Pediatric Neurological Disorders
Keywords
fetal circulation, fetal blood flow, reference values, phase-contrast MRI, fetal hemodynamics, pulmonary blood flow, ductus arteriosus, umbilical vein, fetal aorta, fetal pulmonary artery, term fetus, fetal weight estimation
MeSH terms
Adult, Arteries, Cross-Sectional Studies, Female, Fetal Diseases, Fetus, Gestational Age, Humans, Pregnancy, Prenatal Diagnosis, Prospective Studies, Reference Values, Regional Blood Flow, Vascular Diseases, Reproducibility of Results, Magnetic Resonance Imaging, Cine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review