Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 240

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Sex- and Method-Specific Reference Values for Right Ventricular Strain by 2-Dimensional Speckle-Tracking Echocardiography

Open access
Muraru, Denisa, Onciul, Sebastian, Peluso, Diletta, Soriani, Nicola, Cucchini, Umberto, Aruta, Patrizia, Romeo, Gabriella, Cavalli, Giacomo, Iliceto, Sabino, Badano, Luigi P. · 2016 · Circulation: Cardiovascular Imaging

Abstract

Background—: Despite the fact that assessment of right ventricular longitudinal strain (RVLS) carries important implications for patient diagnosis, prognosis, and treatment, its implementation in clinical settings has been hampered by the limited reference values and the lack of uniformity in software, method, and definition used for measuring RVLS. Accordingly, this study was designed to establish (1) the reference values for RVLS by 2-dimensional speckle-tracking echocardiography; and (2) their relationship with demographic, hemodynamic, and cardiac factors. Methods and Results—: In 276 healthy volunteers (55% women; age, 18–76 years), free wall and septum RVLS (6 segments) and free wall RVLS (3 segments) using both 6- and 3-segment regions of interest were obtained. Feasibility of 6-segment RVLS was 92%. Free wall RVLS from 3- versus 6-segment regions of interest had similar values, yet 6-segment region of interest was more feasible (86% versus 73%; P <0.001) and reproducible. Reference values (lower limits of normality) were as follows: 6-segment RVLS, −24.7±2.6% (−20.0%) for men and −26.7±3.1% (−20.3%) for women; 3-segment RVLS, −29.3±3.4% (−22.5%) for men and −31.6±4.0% (−23.3%) for women ( P <0.001). Free wall RVLS was 5±2 strain units (%) larger in magnitude than 6-segment RVLS, 10±4% larger than septal RVLS, and 2±4% larger in women than in men ( P <0.001). At multivariable analysis, age, sex, pulmonary systolic pressure, right atrial minimal volume, as well as right atrial and left ventricular longitudinal strain resulted as correlates of RVLS values. Conclusions—: This is the largest study providing sex- and method-specific reference values for RVLS. Our data may foster the implementation of 2-dimensional speckle-tracking echocardiography–derived RV analysis in clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.115.003866

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 240

Metadata

Authors
Muraru, D., Onciul, S., Peluso, D., Soriani, N., Cucchini, U., Aruta, P., Romeo, G., Cavalli, G., Iliceto, S., & Badano, L. P.
Venue
Circulation: Cardiovascular Imaging
Published
2016-02
Volume
9
Issue
2
Pages
e003866-e003866
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2553561245
Cited by
240
References
1
FWCI
16.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sex- and Method-Specific Reference Values for Right Ventricular Strain by 2-Dimensional Speckle-Tracking Echocardiography. https://app.cochat.ai/papers/10.1161/circimaging.115.003866
The paper
Muraru, D., Onciul, S., Peluso, D., Soriani, N., Cucchini, U., Aruta, P., Romeo, G., Cavalli, G., Iliceto, S., & Badano, L. P. (2016). Sex- and Method-Specific Reference Values for Right Ventricular Strain by 2-Dimensional Speckle-Tracking Echocardiography. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.115.003866

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.