The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection: A Systematic Review and Meta-Analysis
Abstract
Background—: The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography , labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results—: A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%–91%) and pooled specificity was 94% (95% CI, 88%–98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions—: Both 18 F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for 18 F-FDG PET-CT but limited data for LS. When available, 18 F-FDG PET-CT may be preferred.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Cited by
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · EP Europace · doi:10.1093/europace/euz246 · Cited by 423
Blomström-Lundqvist, C., Traykov, V., Erba, P. A., Burri, H., Nielsen, J. C., Bongiorni, M. G., Poole, J., Boriani, G., Costa, R., Deharo, J.-C., et al. (2020) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz296 · Cited by 318
Targeting Cardiovascular Implant Infection: Multimodality and Molecular Imaging
Sohns, J. M., Bavendiek, U., Ross, T. L., & Bengel, F. M. (2017) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.005376 · Cited by 24
Metadata
- Authors
- Juneau, D., Golfam, M., Hazra, S., Zuckier, L. S., Garas, S., Redpath, C., Bernick, J., Leung, E., Chih, S., Wells, G., Beanlands, R. S. B., & Chow, B. J. W.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2017-04
- Volume
- 10
- Issue
- 4
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2604916385
- Cited by
- 160
- References
- 1
- FWCI
- 13.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.