Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Validation of Intravascular Ultrasound–Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity

Open access
Kang, Soo-Jin, Lee, Jong-Young, Ahn, Jung-Min, Mintz, Gary S., Kim, Won-Jang, Park, Duk-Woo, Yun, Sung-Cheol, Lee, Seung-Whan, Kim, Young-Hak, Whan Lee, Cheol, Park, Seong-Wook, Park, Seung-Jung · 2011 · Circulation: Cardiovascular Interventions

Abstract

Background—: We assessed optimal intravascular ultrasound (IVUS) criteria for predicting functional significance of intermediate coronary lesions. Methods and Results—: Overall, 201 patients with 236 coronary lesions underwent IVUS and invasive physiological assessment before intervention. Fractional flow reserve (FFR) was measured at maximal hyperemia induced by intravenous adenosine infusion. FFR <0.80 at maximum hyperemia was seen in 49 (21%) of the overall 236 lesions. The independent determinants of FFR were minimal lumen area (MLA; β=0.020; 95% confidence interval [CI], 0.008 to 0.031; P =0.032), plaque burden (β=−0.002; 95% CI, −0.003 to 0.001; P =0.001), lesion length with a lumen area <3.0 mm 2 (β=−0.003; 95% CI, −0.005 to −0.001; P =0.005), and left anterior descending artery location (β=−0.035; 95% CI, −0.055 to −0.016; P =0.001). The best cutoff value (with a maximal accuracy) of the MLA to predict FFR <0.80 was <2.4 mm 2 , with a diagnostic accuracy of 68% (90% sensitivity, 60% specificity, and area under the curve=0.800; 95% CI, 0.742 to 0.848; P <0.001). The cutoff value of plaque burden to predict FFR <0.80 was ≥79% (69% sensitivity, 72% specificity, and area under the curve=0.756; 95% CI, 0.696 to 0.810; P <0.001). The cutoff value of lesion length with a lumen area <3.0 mm 2 was 3.1 mm (84%sensitivity, 63%specificity, and area under the curve=0.765; 95% CI, 0.706 to 0.818; P <0.001). Among 117 lesions with an MLA ≥2.4 mm 2 , 112 (96%) had an FFR ≥0.80,; and all but 1 showed FFR ≥0.75. Conversely, 44 (37%) lesions with an MLA <2.4 mm 2 had an FFR <0.80. Conclusions—: IVUS-derived MLA ≥2.4 mm 2 may be useful to exclude FFR <0.80, but poor specificity limits its value for physiological assessment of lesions with MLA <2.4 mm 2 . Thus, FFR or stress tests may be necessary to accurately identify ischemia-inducible intermediate stenoses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.110.959148

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 203

Metadata

Authors
Kang, S.-J., Lee, J.-Y., Ahn, J.-M., Mintz, G. S., Kim, W.-J., Park, D.-W., Yun, S.-C., Lee, S.-W., Kim, Y.-H., Whan Lee, C., Park, S.-W., & Park, S.-J.
Venue
Circulation: Cardiovascular Interventions
Published
2011-02
Volume
4
Issue
1
Pages
65-71
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W1983862722
Cited by
203
References
1
FWCI
30.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of Intravascular Ultrasound–Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity. https://app.cochat.ai/papers/10.1161/circinterventions.110.959148
The paper
Kang, S.-J., Lee, J.-Y., Ahn, J.-M., Mintz, G. S., Kim, W.-J., Park, D.-W., Yun, S.-C., Lee, S.-W., Kim, Y.-H., Whan Lee, C., Park, S.-W., & Park, S.-J. (2011). Validation of Intravascular Ultrasound–Derived Parameters With Fractional Flow Reserve for Assessment of Coronary Stenosis Severity. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.110.959148

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.