Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Long-Term Safety of an Everolimus-Eluting Bioresorbable Vascular Scaffold and the Cobalt-Chromium XIENCE V Stent in a Porcine Coronary Artery Model

Otsuka, Fumiyuki, Pacheco, Erica, Perkins, Laura E.L., Lane, Jennifer P., Wang, Qing, Kamberi, Marika, Frie, Michael, Wang, Jin, Sakakura, Kenichi, Yahagi, Kazuyuki, Ladich, Elena, Rapoza, Richard J., Kolodgie, Frank D., Virmani, Renu · 2014 · Circulation: Cardiovascular Interventions

Abstract

Background—: The Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb) has shown promising clinical results; however, only limited preclinical data have been published. We sought to investigate detailed pathological responses to the Absorb versus XIENCE V (XV) in a porcine coronary model with duration of implant extending from 1 to 42 months. Methods and Results—: A total of 335 devices (263 Absorb and 72 XV) were implanted in 2 or 3 main coronary arteries of 136 nonatherosclerotic swine and examined by light microscopy, scanning electron microscopy, pharmacokinetics, and gel permeation chromatography analyses at various time points. Vascular responses to Absorb and XV were largely comparable at all time points, with struts being sequestered within the neointima. Inflammation was mild to moderate (with absence of inflammation at 1 month) for both devices, although the scores were greater in Absorb at 6 to 36 months. Percent area stenosis was significantly greater in Absorb than XV at all time points except at 3 months. The extent of fibrin deposition was similar between Absorb and XV, which peaked at 1 month and decreased rapidly thereafter. Histomorphometry showed expansile remodeling of Absorb-implanted arteries starting after 12 months, and lumen area was significantly greater in Absorb than XV at 36 and 42 months. These changes correlated with dismantling of Absorb seen after 12 months. Gel permeation chromatography analysis confirmed that degradation of Absorb was complete by 36 months. Conclusions—: Absorb demonstrates comparable long-term safety to XV in porcine coronary arteries with mild to moderate inflammation. Although Absorb was associated with greater percent stenosis relative to XV, expansile remodeling was observed after 12 months in Absorb with significantly greater lumen area at ≥36 months. Resorption is considered complete at 36 months.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.113.000990

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Otsuka, F., Pacheco, E., Perkins, L. E. L., Lane, J. P., Wang, Q., Kamberi, M., Frie, M., Wang, J., Sakakura, K., Yahagi, K., Ladich, E., Rapoza, R. J., Kolodgie, F. D., & Virmani, R.
Venue
Circulation: Cardiovascular Interventions
Published
2014-06
Volume
7
Issue
3
Pages
330-342
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2099871228
Cited by
176
References
2
FWCI
25.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.