Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Intracoronary Delivery of Injectable Bioabsorbable Scaffold (IK-5001) to Treat Left Ventricular Remodeling After ST-Elevation Myocardial Infarction: A First-in-Man Study

Frey, Norbert, Linke, Axel, Süselbeck, Tim, Müller-Ehmsen, Jochen, Vermeersch, Paul, Schoors, Danny, Rosenberg, Mark, Bea, Florian, Tuvia, Shmuel, Leor, Jonathan·2014·Circulation: Cardiovascular Interventions

Abstract

Background—: We aimed to test, for the first time, the feasibility of intracoronary delivery of an innovative, injectable bioabsorbable scaffold (IK-5001), to prevent or reverse adverse left ventricular remodeling and dysfunction in patients after ST-segment–elevation myocardial infarction. Methods and Results—: Patients (n=27) with moderate-to-large ST-segment–elevation myocardial infarctions, after successful revascularization, were enrolled. Two milliliters of IK-5001, a solution of 1% sodium alginate plus 0.3% calcium gluconate, was administered by selective injection through the infarct-related coronary artery within 7 days after myocardial infarction. IK-5001 is assumed to permeate the infarcted tissue, cross-linking into a hydrogel and forming a bioabsorbable cardiac scaffold. Coronary angiography, 3 minutes after injection, confirmed that the injection did not impair coronary flow and myocardial perfusion. Furthermore, IK-5001 deployment was not associated with additional myocardial injury or re-elevation of cardiac biomarkers. Clinical assessments, echocardiographic studies, 12-lead electrocardiograms, 24-hour Holter monitoring, blood tests, and completion of Minnesota Living with Heart Failure Questionnaires were repeated during follow-up visits at 30, 90, and 180 days after treatment. During a 6-month follow-up, these tests confirmed favorable tolerability of the procedure, without device-related adverse events, serious arrhythmias, blood test abnormalities, or death. Serial echocardiographic studies showed preservation of left ventricular indices and left ventricular ejection fraction. Conclusions—: This first-in-man pilot study shows that intracoronary deployment of an IK-5001 scaffold is feasible and well tolerated. Our results have promoted the initiation of a multicenter, randomized controlled trial to confirm the safety and efficacy of this new approach in high-risk patients after ST-segment–elevation myocardial infarction. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01226563.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.114.001478

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 160

Metadata

Authors
Frey, N., Linke, A., Süselbeck, T., Müller-Ehmsen, J., Vermeersch, P., Schoors, D., Rosenberg, M., Bea, F., Tuvia, S., & Leor, J.
Venue
Circulation: Cardiovascular Interventions
Published
2014-12
Volume
7
Issue
6
Pages
806-812
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2547776764
Cited by
160
References
1
FWCI
9.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intracoronary Delivery of Injectable Bioabsorbable Scaffold (IK-5001) to Treat Left Ventricular Remodeling After ST-Elevation Myocardial Infarction: A First-in-Man Study. https://app.cochat.ai/papers/10.1161/circinterventions.114.001478
The paper
Frey, N., Linke, A., Süselbeck, T., Müller-Ehmsen, J., Vermeersch, P., Schoors, D., Rosenberg, M., Bea, F., Tuvia, S., & Leor, J. (2014). Intracoronary Delivery of Injectable Bioabsorbable Scaffold (IK-5001) to Treat Left Ventricular Remodeling After ST-Elevation Myocardial Infarction: A First-in-Man Study. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.114.001478

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.