The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis
Open accessAbstract
Background—: Valve thrombosis has yet to be fully evaluated after transcatheter aortic valve implantation. This study aimed to report the prevalence, timing, and treatment of transcatheter heart valve (THV) thrombosis. Methods and Results—: THV thrombosis was defined as follows (1) THV dysfunction secondary to thrombosis diagnosed based on response to anticoagulation therapy, imaging modality or histopathology findings, or (2) mobile mass detected on THV suspicious of thrombus, irrespective of dysfunction and in absence of infection. Between January 2008 and September 2013, 26 (0.61%) THV thromboses were reported out of 4266 patients undergoing transcatheter aortic valve implantation in 12 centers. Of the 26 cases detected, 20 were detected in the Edwards Sapien/Sapien XT cohort and 6 in the Medtronic CoreValve cohort. In patients diagnosed with THV thrombosis, the median time to THV thrombosis post–transcatheter aortic valve implantation was 181 days (interquartile range, 45–313). The most common clinical presentation was exertional dyspnea (n=17; 65%), whereas 8 (31%) patients had no worsening symptoms. Echocardiographic findings included a markedly elevated mean aortic valve pressure gradient (40.5±14.0 mm Hg), presence of thickened leaflets or thrombotic apposition of leaflets in 20 (77%) and a thrombotic mass on the leaflets in the remaining 6 (23%) patients. In 23 (88%) patients, anticoagulation resulted in a significant decrease of the aortic valve pressure gradient within 2 months. Conclusions—: THV thrombosis is a rare phenomenon that was detected within the first 2 years after transcatheter aortic valve implantation and usually presented with dyspnea and increased gradients. Anticoagulation seems to have been effective and should be considered even in patients without visible thrombus on echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Self-citationTranscatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Self-citationAuthors/Task Force Members, Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl428 · Cited by 3,593
Self-citationTwo-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Self-citationGuidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezs455 · Cited by 2,009
Self-citationTranscatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
Self-citationLeon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq406 · Cited by 1,219
Self-citationHammermeister, K., Sethi, G. K., Henderson, W. G., Grover, F. L., Oprian, C., & Rahimtoola, S. H. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00834-2 · Cited by 1,144
Tamburino, C., Capodanno, D., Ramondo, A., Petronio, A. S., Ettori, F., Santoro, G., Klugmann, S., Bedogni, F., Maisano, F., Marzocchi, A., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.946533 · Cited by 1,124
Self-citationStandardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials
Leon, M. B., Piazza, N., Nikolsky, E., Blackstone, E. H., Cutlip, D. E., Kappetein, A. P., Krucoff, M. W., Mack, M., Mehran, R., Miller, C., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.005 · Cited by 733
Self-citation
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.011 · Cited by 3,339
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Fleisher, L. A., Jneid, H., Mack, M. J., McLeod, C. J., O’Gara, P. T., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000503 · Cited by 2,497
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.11.018 · Cited by 1,982
Metadata
- Authors
- Latib, A., Naganuma, T., Abdel-Wahab, M., Danenberg, H., Cota, L., Barbanti, M., Baumgartner, H., Finkelstein, A., Legrand, V., de Lezo, J. S., Kefer, J., Messika-Zeitoun, D., Richardt, G., Stabile, E., Kaleschke, G., Vahanian, A., Laborde, J.-C., Leon, M. B., Webb, J. G., Panoulas, V. F., Maisano, F., Alfieri, O., & Colombo, A.
- Venue
- Circulation: Cardiovascular Interventions
- Published
- 2015-04
- Volume
- 8
- Issue
- 4
- ISSN
- 1941-7632 (ISSN-L)
- 1941-7640
- OpenAlex
- W2085174670
- Cited by
- 293
- References
- 25
- FWCI
- 30.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis. https://app.cochat.ai/papers/10.1161/circinterventions.114.001779
- The paper
- Latib, A., Naganuma, T., Abdel-Wahab, M., Danenberg, H., Cota, L., Barbanti, M., Baumgartner, H., Finkelstein, A., Legrand, V., de Lezo, J. S., Kefer, J., Messika-Zeitoun, D., Richardt, G., Stabile, E., Kaleschke, G., Vahanian, A., Laborde, J.-C., Leon, M. B., Webb, J. G., . . . Colombo, A. (2015). Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.114.001779
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.