Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis

Open access
Latib, Azeem, Naganuma, Toru, Abdel-Wahab, Mohamed, Danenberg, Haim, Cota, Linda, Barbanti, Marco, Baumgartner, Helmut, Finkelstein, Ariel, Legrand, Victor, de Lezo, José Suárez, Kefer, Joelle, Messika-Zeitoun, David, Richardt, Gert, Stabile, Eugenio, Kaleschke, Gerrit, Vahanian, Alec, Laborde, Jean-Claude, Leon, Martin B., Webb, John G., Panoulas, Vasileios F., Maisano, Francesco, Alfieri, Ottavio, Colombo, Antonio · 2015 · Circulation: Cardiovascular Interventions

Abstract

Background—: Valve thrombosis has yet to be fully evaluated after transcatheter aortic valve implantation. This study aimed to report the prevalence, timing, and treatment of transcatheter heart valve (THV) thrombosis. Methods and Results—: THV thrombosis was defined as follows (1) THV dysfunction secondary to thrombosis diagnosed based on response to anticoagulation therapy, imaging modality or histopathology findings, or (2) mobile mass detected on THV suspicious of thrombus, irrespective of dysfunction and in absence of infection. Between January 2008 and September 2013, 26 (0.61%) THV thromboses were reported out of 4266 patients undergoing transcatheter aortic valve implantation in 12 centers. Of the 26 cases detected, 20 were detected in the Edwards Sapien/Sapien XT cohort and 6 in the Medtronic CoreValve cohort. In patients diagnosed with THV thrombosis, the median time to THV thrombosis post–transcatheter aortic valve implantation was 181 days (interquartile range, 45–313). The most common clinical presentation was exertional dyspnea (n=17; 65%), whereas 8 (31%) patients had no worsening symptoms. Echocardiographic findings included a markedly elevated mean aortic valve pressure gradient (40.5±14.0 mm Hg), presence of thickened leaflets or thrombotic apposition of leaflets in 20 (77%) and a thrombotic mass on the leaflets in the remaining 6 (23%) patients. In 23 (88%) patients, anticoagulation resulted in a significant decrease of the aortic valve pressure gradient within 2 months. Conclusions—: THV thrombosis is a rare phenomenon that was detected within the first 2 years after transcatheter aortic valve implantation and usually presented with dyspnea and increased gradients. Anticoagulation seems to have been effective and should be considered even in patients without visible thrombus on echocardiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.114.001779

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 293

Metadata

Authors
Latib, A., Naganuma, T., Abdel-Wahab, M., Danenberg, H., Cota, L., Barbanti, M., Baumgartner, H., Finkelstein, A., Legrand, V., de Lezo, J. S., Kefer, J., Messika-Zeitoun, D., Richardt, G., Stabile, E., Kaleschke, G., Vahanian, A., Laborde, J.-C., Leon, M. B., Webb, J. G., Panoulas, V. F., Maisano, F., Alfieri, O., & Colombo, A.
Venue
Circulation: Cardiovascular Interventions
Published
2015-04
Volume
8
Issue
4
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2085174670
Cited by
293
References
25
FWCI
30.78
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis. https://app.cochat.ai/papers/10.1161/circinterventions.114.001779
The paper
Latib, A., Naganuma, T., Abdel-Wahab, M., Danenberg, H., Cota, L., Barbanti, M., Baumgartner, H., Finkelstein, A., Legrand, V., de Lezo, J. S., Kefer, J., Messika-Zeitoun, D., Richardt, G., Stabile, E., Kaleschke, G., Vahanian, A., Laborde, J.-C., Leon, M. B., Webb, J. G., . . . Colombo, A. (2015). Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.114.001779

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.