Association of Rapid Care Process Implementation on Reperfusion Times Across Multiple ST-Segment–Elevation Myocardial Infarction Networks

Open access
Fordyce, Christopher B., Al-Khalidi, Hussein R., Jollis, James G., Roettig, Mayme L., Gu, Joan, Bagai, Akshay, Berger, Peter B., Corbett, Claire C., Dauerman, Harold L., Fox, Kathleen, Garvey, J. Lee, Henry, Timothy D., Rokos, Ivan C., Sherwood, Matthew W., Wilson, B. Hadley, Granger, Christopher B. · 2017 · Circulation: Cardiovascular Interventions
Cited by 64

The DOI matches its Crossref record.

Abstract

Background—: The Mission: Lifeline STEMI Systems Accelerator program, implemented in 16 US metropolitan regions, resulted in more patients receiving timely reperfusion. We assessed whether implementing key care processes was associated with system performance improvement. Methods and Results—: Hospitals (n=167 with 23 498 ST-segment–elevation myocardial infarction patients) were surveyed before (March 2012) and after (July 2014) program intervention. Data were merged with patient-level clinical data over the same period. For reperfusion, hospitals were grouped by whether a specific process of care was implemented, preexisting, or never implemented. Uptake of 4 key care processes increased after intervention: prehospital catheterization laboratory activation (62%–91%; P <0.001), single call transfer protocol from an outside facility (45%–70%; P <0.001), and emergency department bypass for emergency medical services direct presenters (48%–59%; P =0.002) and transfers (56%–79%; P =0.001). There were significant differences in median first medical contact-to-device times among groups implementing prehospital activation (88 minutes implementers versus 89 minutes preexisting versus 98 minutes nonimplementers; P <0.001 for comparisons). Similarly, patients treated at hospitals implementing single call transfer protocols had shorter median first medical contact-to-device times (112 versus 128 versus 152 minutes; P <0.001). Emergency department bypass was also associated with shorter median first medical contact-to-device times for emergency medical services direct presenters (84 versus 88 versus 94 minutes; P <0.001) and transfers (123 versus 127 versus 167 minutes; P <0.001). Conclusions—: The Accelerator program increased uptake of key care processes, which were associated with improved system performance. These findings support efforts to implement regional ST-segment–elevation myocardial infarction networks focused on prehospital catheterization laboratory activation, single call transfer protocols, and emergency department bypass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circinterventions.116.004061

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Fordyce, C. B., Al-Khalidi, H. R., Jollis, J. G., Roettig, M. L., Gu, J., Bagai, A., Berger, P. B., Corbett, C. C., Dauerman, H. L., Fox, K., Garvey, J. L., Henry, T. D., Rokos, I. C., Sherwood, M. W., Wilson, B. H., & Granger, C. B.
Venue
Circulation: Cardiovascular Interventions
Published
2017-01
Volume
10
Issue
1
ISSN
  • 1941-7632 (ISSN-L)
  • 1941-7640
OpenAlex
W2577406456
Cited by
64
References
0
FWCI
4.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.