Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Development and Validation of a Short Version of the Seattle Angina Questionnaire

Open access
Chan, Paul S., Jones, Philip G., Arnold, Suzanne A., Spertus, John A.·2014·Circulation: Cardiovascular Quality and Outcomes

Abstract

Background—: Clinical trials and national performance measures increasingly mandate reporting patients’ perspectives of their health status: their symptoms, function, and quality of life. Although the Seattle Angina Questionnaire (SAQ) is a validated disease-specific health status instrument for coronary artery disease (CAD) with high test–retest reliability, predictive power, and responsiveness, its use in routine clinical practice has been limited, in part, by its length (19 items). Methods and Results—: Using data from 10 408 patients with CAD from 5 multicenter registries, we derived and validated a shortened version of the SAQ (SAQ-7) among patients presenting with stable CAD, undergoing percutaneous coronary intervention, and after acute myocardial infarction. We examined the psychometric properties of the SAQ-7 as compared with the full SAQ. Seven items from the Physical Limitation, Angina Frequency, and Quality of Life domains were identified for the SAQ-7, with high levels of concordance (0.88–1.00) with each original SAQ domain. The SAQ-7 demonstrated good construct validity (compared with Canadian Cardiovascular Society class for angina), with a correlation of 0.62 and 0.38 for patients with stable CAD and undergoing percutaneous coronary intervention, respectively. It was highly reproducible in patients with stable CAD (intraclass correlation, ≥0.78) and exhibited excellent responsiveness in patients after percutaneous coronary intervention (≥18 points in each SAQ domain). Finally, the SAQ-7 was predictive of 1-year mortality and readmission. Conclusions—: To increase the feasibility of measuring patient-reported outcomes in patients with CAD, we developed and validated a shortened 7-item SAQ instrument for use in clinical trials and routine care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circoutcomes.114.000967

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 297

Metadata

Authors
Chan, P. S., Jones, P. G., Arnold, S. A., & Spertus, J. A.
Venue
Circulation: Cardiovascular Quality and Outcomes
Published
2014-09
Volume
7
Issue
5
Pages
640-647
ISSN
  • 1941-7705 (ISSN-L)
  • 1941-7713
OpenAlex
W2156024415
Cited by
297
References
34
FWCI
59.79
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Validation of a Short Version of the Seattle Angina Questionnaire. https://app.cochat.ai/papers/10.1161/circoutcomes.114.000967
The paper
Chan, P. S., Jones, P. G., Arnold, S. A., & Spertus, J. A. (2014). Development and Validation of a Short Version of the Seattle Angina Questionnaire. Circulation: Cardiovascular Quality and Outcomes. https://doi.org/10.1161/circoutcomes.114.000967

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.