The DOI matches its Crossref record.
The Glycocalyx of the Human Umbilical Vein Endothelial Cell: An Impressive Structure Ex Vivo but Not in Culture
Open accessAbstract
Potter and Damiano recently assessed the hydrodynamic dimensions of the endothelial glycocalyx in vivo (mouse cremaster muscle venules) and in vitro (human umbilical vein and bovine aorta endothelium cultured in perfused microchannels) using fluorescent microparticle image velocimetry ( Circ Res . 2008;102:770–776). Great discrepancy was observed, the glycocalyx presenting a zone of interaction extending ≈0.52 μm into the vessel lumen in vivo, but only 0.02 to 0.03 μm from cultured cells. In an accompanying editorial, Barakat cautioned that the difference in hydrodynamic interaction did not allow one to conclude that the cultured cells totally lack a physical cell surface layer capable of mechanotransduction ( Circ Res . 2008;102:747–748). To stabilize the glycocalyx for electron microscopic investigation, we perfusion-fixed 6 human umbilical veins and confluent and nonconfluent cultures (5 each) of human umbilical vein endothelial cells (HUVECs) with lanthanum/glutaraldehyde solution. Ex vivo, the thickness of glycocalyx of umbilical vein endothelium averaged 878 nm. HUVECs in vitro presented a glycocalyx with a dense-zone thickness of only 29.4 nm, plus sparse filaments reaching out on average to 118 nm, there being no difference between the nonconfluent and confluent cells. Immunohistology demonstrated the presence of heparan sulfates and syndecan-1, main constituents of the glycocalyx, both ex vivo and in vitro. These results support the observed discrepancy between glycocalyx thickness in vivo and in vitro, now for one and the same type of human cell. The presence of heparan sulfates and syndecan-1 also on cultured cells may explain why mechanotransduction phenomena can be observed even with a nonmature glycocalyx.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schmidt, E. P., Yang, Y., Janssen, W. J., Gandjeva, A., Perez, M. J., Barthel, L., Zemans, R. L., Bowman, J. C., Koyanagi, D. E., Yunt, Z. X., et al. (2012) · Nature Medicine · doi:10.1038/nm.2843 · Cited by 848
Woodcock, T. E., & Woodcock, T. M. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aer515 · Cited by 806
The glycocalyx: a novel diagnostic and therapeutic target in sepsis
Uchimido, R., Schmidt, E. P., & Shapiro, N. I. (2019) · Critical Care · doi:10.1186/s13054-018-2292-6 · Cited by 710
Vascular endothelium – Gatekeeper of vessel health
Cahill, P. A., & Redmond, E. M. (2016) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2016.03.007 · Cited by 518
Degradation of the endothelial glycocalyx in clinical settings: searching for the sheddases
Becker, B. F., Jacob, M., Leipert, S., Salmon, A. H. J., & Chappell, D. (2015) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12629 · Cited by 464
Self-citation
Metadata
- Authors
- Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F.
- Venue
- Circulation Research
- Published
- 2009-06-05
- Volume
- 104
- Issue
- 11
- Pages
- 1313-1317
- ISSN
- 0009-7330 (ISSN-L)
- 1524-4571
- OpenAlex
- W2020732104
- Cited by
- 218
- References
- 0
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Glycocalyx of the Human Umbilical Vein Endothelial Cell: An Impressive Structure Ex Vivo but Not in Culture. https://app.cochat.ai/papers/10.1161/circresaha.108.187831
- The paper
- Chappell, D., Jacob, M., Paul, O., Rehm, M., Welsch, U., Stoeckelhuber, M., Conzen, P., & Becker, B. F. (2009). The Glycocalyx of the Human Umbilical Vein Endothelial Cell: An Impressive Structure Ex Vivo but Not in Culture. Circulation Research. https://doi.org/10.1161/circresaha.108.187831
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.