CoChat

HCN3 Contributes to the Ventricular Action Potential Waveform in the Murine Heart

Open access
Fenske, Stefanie, Mader, Robert, Scharr, Andreas, Paparizos, Christos, Cao-Ehlker, Xiaochun, Michalakis, Stylianos, Shaltiel, Lior, Weidinger, Martha, Stieber, Juliane, Feil, Susanne, Feil, Robert, Hofmann, Franz, Wahl-Schott, Christian, Biel, Martin · 2011 · Circulation Research
Cited by 71

The DOI matches its Crossref record.

Abstract

Rationale: The hyperpolarization-activated current I h that is generated by hyperpolarization-activated cyclic nucleotide-gated channels (HCNs) plays a key role in the control of pacemaker activity in sinoatrial node cells of the heart. By contrast, it is unclear whether I h is also relevant for normal function of cardiac ventricles. Objective: To study the role of the HCN3-mediated component of ventricular I h in normal ventricular function. Methods and Results: To test the hypothesis that HCN3 regulates the ventricular action potential waveform, we have generated and analyzed a HCN3-deficient mouse line. At basal heart rate, mice deficient for HCN3 displayed a profound increase in the T-wave amplitude in telemetric electrocardiographic measurements. Action potential recordings on isolated ventricular myocytes indicate that this effect was caused by an acceleration of the late repolarization phase in epicardial myocytes. Furthermore, the resting membrane potential was shifted to more hyperpolarized potentials in HCN3-deficient mice. Cardiomyocytes of HCN3-deficient mice displayed approximately 30% reduction of total I h . At physiological ionic conditions, the HCN3-mediated current had a reversal potential of approximately −35 mV and displayed ultraslow deactivation kinetics. Conclusions: We propose that HCN3 together with other members of the HCN channel family confer a depolarizing background current that regulates ventricular resting potential and counteracts the action of hyperpolarizing potassium currents in late repolarization. In conclusion, our data indicate that HCN3 plays an important role in shaping the cardiac action potential waveform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circresaha.111.246173

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Fenske, S., Mader, R., Scharr, A., Paparizos, C., Cao-Ehlker, X., Michalakis, S., Shaltiel, L., Weidinger, M., Stieber, J., Feil, S., Feil, R., Hofmann, F., Wahl-Schott, C., & Biel, M.
Venue
Circulation Research
Published
2011-10-14
Volume
109
Issue
9
Pages
1015-1023
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W2161654300
Cited by
71
References
0
FWCI
4.51
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HCN3 Contributes to the Ventricular Action Potential Waveform in the Murine Heart. https://app.cochat.ai/papers/10.1161/circresaha.111.246173
The paper
Fenske, S., Mader, R., Scharr, A., Paparizos, C., Cao-Ehlker, X., Michalakis, S., Shaltiel, L., Weidinger, M., Stieber, J., Feil, S., Feil, R., Hofmann, F., Wahl-Schott, C., & Biel, M. (2011). HCN3 Contributes to the Ventricular Action Potential Waveform in the Murine Heart. Circulation Research. https://doi.org/10.1161/circresaha.111.246173

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.