Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 584

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Utility of Cardiac Magnetic Resonance Imaging in the Diagnosis of Hypertrophic Cardiomyopathy

Open access
Rickers, Carsten, Wilke, Norbert M., Jerosch-Herold, Michael, Casey, Susan A., Panse, Prasad, Panse, Neeta, Weil, Jochen, Zenovich, Andrey G., Maron, Barry J.·2005·Circulation

Abstract

Background— Two-dimensional echocardiography is currently the standard test for the clinical diagnosis of hypertrophic cardiomyopathy (HCM). The present study was undertaken to determine whether cardiac MRI (CMR) affords greater accuracy than echocardiography in establishing the diagnosis and assessing the magnitude of left ventricular (LV) hypertrophy in HCM. Methods and Results— Forty-eight patients (age 34±16 years) suspected of having HCM (or with a confirmed diagnosis) were imaged by both echocardiography and CMR to assess LV wall thickness in 8 anatomic segments (total n=384 segments) and compared in a blinded fashion. Maximum LV thickness was similar by echocardiography (21.7±9.1 mm) and CMR (22.5±9.6 mm; P =0.21). However, in 3 (6%) of the 48 patients, echocardiography did not demonstrate LV hypertrophy, and CMR identified otherwise undetected areas of wall thickening in the anterolateral LV free wall (17 to 20 mm), which resulted in a new diagnosis of HCM. In the overall study group, compared with CMR, echocardiography also underestimated the magnitude of hypertrophy in the basal anterolateral free wall (by 20±6%; P =0.001), as well as the presence of extreme LV wall thickness (≥30 mm) in 10% of patients ( P <0.05). Conclusions— CMR is capable of identifying regions of LV hypertrophy not readily recognized by echocardiography and was solely responsible for diagnosis of the HCM phenotype in an important minority of patients. CMR enhances the assessment of LV hypertrophy, particularly in the anterolateral LV free wall, and represents a powerful supplemental imaging test with distinct diagnostic advantages for selected HCM patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.507723

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 584

Metadata

Authors
Rickers, C., Wilke, N. M., Jerosch-Herold, M., Casey, S. A., Panse, P., Panse, N., Weil, J., Zenovich, A. G., & Maron, B. J.
Venue
Circulation
Published
2005-08-09
Volume
112
Issue
6
Pages
855-861
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2054853747
Cited by
584
References
3
FWCI
17.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Utility of Cardiac Magnetic Resonance Imaging in the Diagnosis of Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1161/circulationaha.104.507723
The paper
Rickers, C., Wilke, N. M., Jerosch-Herold, M., Casey, S. A., Panse, P., Panse, N., Weil, J., Zenovich, A. G., & Maron, B. J. (2005). Utility of Cardiac Magnetic Resonance Imaging in the Diagnosis of Hypertrophic Cardiomyopathy. Circulation. https://doi.org/10.1161/circulationaha.104.507723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.