Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record.

Assessment of Temperature, Proximity, and Course of the Esophagus During Radiofrequency Ablation Within the Left Atrium

Open access
Cummings, Jennifer E., Schweikert, Robert A., Saliba, Walid I., Burkhardt, J. David, Brachmann, Johannes, Gunther, Jens, Schibgilla, Volker, Verma, Atul, Dery, MarkAlain, Drago, John L., Kilicaslan, Fethi, Natale, Andrea · 2005 · Circulation

Abstract

Background— Left atrioesophageal fistula is a devastating complication of atrial fibrillation ablation. There is no standard approach for avoiding this complication, which is caused by thermal injury during ablation. The objectives of this study were to evaluate the course of the esophagus and the temperature within the esophagus during pulmonary vein antrum isolation (PVAI) and correlate these data with esophagus tissue damage. Methods and Results— Eight-one patients presenting for PVAI underwent esophagus evaluation that included temperature probe placement. Esophagus course was obtained with computed tomography, 3D imaging (NAVX), or intracardiac echocardiography. For each lesion, the power, catheter and esophagus temperature, location, and presence of microbubbles were recorded. Lesion location and esophagus course were defined with 6 predetermined left atrial anatomic segments. Endoscopy evaluated tissue changes during and after PVAI. Of 81 patients, the esophagus coursed near the right pulmonary veins in 23 (28.4%), left pulmonary veins in 31 (38.3%), and mid-posterior wall in 27 (33%). Esophagus temperature was significantly higher during left atrial lesions along its course than with lesions elsewhere (38.9±1.4°C, 36.8±0.5°C, P <0.01). Lesions that generated microbubbles had higher esophagus temperatures than those without (39.3±1.5°C, 38.5±0.9°C, P <0.01). Power was not predictive of esophagus temperatures. Distance between the esophagus and left atrium was 4.4±1.2 mm. Conclusions— Lesions near the course of the esophagus that generated microbubbles significantly increased esophagus temperature compared with lesions that did not. Power did not correlate with esophagus temperatures. Esophagus variability makes the avoidance of lesions along its course difficult. Rather than avoiding posterior lesions, emphasis could be placed on better esophagus monitoring for creation of safer lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.104.509612

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Cummings, J. E., Schweikert, R. A., Saliba, W. I., Burkhardt, J. D., Brachmann, J., Gunther, J., Schibgilla, V., Verma, A., Dery, M., Drago, J. L., Kilicaslan, F., & Natale, A.
Venue
Circulation
Published
2005-07-26
Volume
112
Issue
4
Pages
459-464
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2149396526
Cited by
203
References
0
FWCI
11.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Temperature, Proximity, and Course of the Esophagus During Radiofrequency Ablation Within the Left Atrium. https://app.cochat.ai/papers/10.1161/circulationaha.104.509612
The paper
Cummings, J. E., Schweikert, R. A., Saliba, W. I., Burkhardt, J. D., Brachmann, J., Gunther, J., Schibgilla, V., Verma, A., Dery, M., Drago, J. L., Kilicaslan, F., & Natale, A. (2005). Assessment of Temperature, Proximity, and Course of the Esophagus During Radiofrequency Ablation Within the Left Atrium. Circulation. https://doi.org/10.1161/circulationaha.104.509612

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.