The DOI matches its Crossref record.
Volume-Outcome Relationships for Percutaneous Coronary Interventions in the Stent Era
Abstract
Background— Most studies that are the basis of recommended volume thresholds for percutaneous coronary interventions (PCIs) predate the routine use of stent placement. Methods and Results— Data from New York’s Percutaneous Coronary Interventions Reporting System in 1998 to 2000 (n=107 713) were used to examine the impact of annual hospital volume and annual operator volume on in-hospital mortality, same-day coronary artery bypass graft (CABG) surgery, and same-stay CABG surgery after adjustment for differences in patients’ severity of illness. For a hospital-volume threshold of 400, the odds ratios for low-volume hospitals versus high-volume hospitals were 1.98 (95% CI, 1.17, 3.35) for in-hospital mortality, 2.07 (95% CI, 1.36, 3.15) for same-day CABG surgery, and 1.51 (95% CI, 1.03, 2.21) for same-stay CABG surgery. For an operator-volume threshold of 75, the odds ratios for low-volume versus high-volume operators were 1.65 (95% CI, 1.05, 2.60) for same-day CABG surgery and 1.55 (95% CI, 1.10, 2.18) for same-stay CABG surgery. Operator volume was not significantly associated with mortality. Also, for hospital volumes below 400 and operator volumes below 75, the respective odds of mortality, same-day CABG surgery, and same-stay CABG surgery were 5.92, 4.02, and 3.92 times the odds for hospital volumes of 400 or higher and operator volumes of 75 or higher. Conclusions— Higher-volume operators and hospitals continue to experience lower risk-adjusted PCI outcome rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
Writing Committee Members, Levine, G. N., Bates, E. R., Blankenship, J. C., Bailey, S. R., Bittl, J. A., Cercek, B., Chambers, C. E., Ellis, S. G., Guyton, R. A., et al. (2011) · Circulation · doi:10.1161/cir.0b013e31823ba622 · Cited by 3,289
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Self-citation
Metadata
- Authors
- Hannan, E. L., Wu, C., Walford, G., King, S. B., Holmes, D. R., Ambrose, J. A., Sharma, S., Katz, S., Clark, L. T., & Jones, R. H.
- Venue
- Circulation
- Published
- 2005-08-23
- Volume
- 112
- Issue
- 8
- Pages
- 1171-1179
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2093422678
- Cited by
- 199
- References
- 0
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume-Outcome Relationships for Percutaneous Coronary Interventions in the Stent Era. https://app.cochat.ai/papers/10.1161/circulationaha.104.528455
- The paper
- Hannan, E. L., Wu, C., Walford, G., King, S. B., Holmes, D. R., Ambrose, J. A., Sharma, S., Katz, S., Clark, L. T., & Jones, R. H. (2005). Volume-Outcome Relationships for Percutaneous Coronary Interventions in the Stent Era. Circulation. https://doi.org/10.1161/circulationaha.104.528455
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.