Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

High-Dose β-Blockers and Tight Heart Rate Control Reduce Myocardial Ischemia and Troponin T Release in Vascular Surgery Patients

Open access
Feringa, Harm H.H., Bax, Jeroen J., Boersma, Eric, Kertai, Miklos D., Meij, Simon H., Galal, Wael, Schouten, Olaf, Thomson, Ian R., Klootwijk, Peter, van Sambeek, Marc R.H.M., Klein, Jan, Poldermans, Don·2006·Circulation

Abstract

Background— Adverse perioperative cardiac events occur frequently despite the use of beta (β)-blockers. We examined whether higher doses of β-blockers and tight heart rate control were associated with reduced perioperative myocardial ischemia and troponin T release and improved long-term outcome. Methods and Results— In an observational cohort study, 272 vascular surgery patients were preoperatively screened for cardiac risk factors and β-blocker dose. Beta-blocker dose was converted to a percentage of maximum recommended therapeutic dose. Heart rate and ischemic episodes were recorded by continuous 12-lead electrocardiography, starting 1 day before to 2 days after surgery. Serial troponin T levels were measured after surgery. All-cause mortality was noted during follow-up. Myocardial ischemia was detected in 85 of 272 (31%) patients and troponin T release in 44 of 272 (16.2%). Long-term mortality occurred in 66 of 272 (24.2%) patients. In multivariate analysis, higher β-blocker doses (per 10% increase) were significantly associated with a lower incidence of myocardial ischemia (hazard ratio [HR], 0.62; 95% confidence interval [CI], 0.51 to 0.75), troponin T release (HR, 0.63; 95% CI, 0.49 to 0.80), and long-term mortality (HR, 0.86; 95% CI, 0.76 to 0.97). Higher heart rates during electrocardiographic monitoring (per 10-bpm increase) were significantly associated with an increased incidence of myocardial ischemia (HR, 2.49; 95% CI, 1.79 to 3.48), troponin T release (HR, 1.53; 95% CI, 1.16 to 2.03), and long-term mortality (HR, 1.42; 95% CI, 1.14 to 1.76). Conclusion— This study showed that higher doses of β-blockers and tight heart rate control are associated with reduced perioperative myocardial ischemia and troponin T release and improved long-term outcome in vascular surgery patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.000463

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Feringa, H. H. H., Bax, J. J., Boersma, E., Kertai, M. D., Meij, S. H., Galal, W., Schouten, O., Thomson, I. R., Klootwijk, P., van Sambeek, M. R. H. M., Klein, J., & Poldermans, D.
Venue
Circulation
Published
2006-07-04
Volume
114
Issue
1_supplement
Pages
I344-9
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2133509153
Cited by
179
References
1
FWCI
22.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Dose β-Blockers and Tight Heart Rate Control Reduce Myocardial Ischemia and Troponin T Release in Vascular Surgery Patients. https://app.cochat.ai/papers/10.1161/circulationaha.105.000463
The paper
Feringa, H. H. H., Bax, J. J., Boersma, E., Kertai, M. D., Meij, S. H., Galal, W., Schouten, O., Thomson, I. R., Klootwijk, P., van Sambeek, M. R. H. M., Klein, J., & Poldermans, D. (2006). High-Dose β-Blockers and Tight Heart Rate Control Reduce Myocardial Ischemia and Troponin T Release in Vascular Surgery Patients. Circulation. https://doi.org/10.1161/circulationaha.105.000463

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.