Magnetic Forces Enable Rapid Endothelialization of Synthetic Vascular Grafts
Open accessThe DOI matches its Crossref record.
Abstract
Background— Synthetic vascular grafts cannot be used in small vessels because of graft failure caused by thrombosis and neointima formation. Rapid endothelialization may overcome this limitation. We hypothesized that a magnetic graft would be able to capture and retain endothelial cells labeled with paramagnetic particles. Methods and Results— Porcine blood derived endothelial cells were allowed to endocytose superparamagnetic iron oxide microspheres. Cell survival was assessed by trypan blue exclusion and demonstrated a dose-dependent cell survival of 75% to 95%. A flexible magnetic sheet was annealed to the external surface of a knitted Dacron graft. Labeled cells (10 6 /mL) were placed within the graft for 5 minutes. Confocal and electron microscopy confirmed uniform cell capture at the magnetized surface. The effect of shear forces on the adherent cells was evaluated in a flow chamber. The cells remained attached at rates up to 300 mL/min, with cell loss commencing at 400 mL/min. Prototype magnetic grafts were implanted in porcine carotid arteries. Labeled cells were placed within the graft for 10 minutes at the time of implantation. The grafts were evaluated after one day and uniform cell coverage was noted on the magnetized surface. In comparison, relatively few labeled cells were seen attached to a nonmagnetized surface. Conclusions— Magnetic forces can be used to rapidly cover a vascular graft with paramagnetically labeled cells. This biophysical interaction is sufficient to retain cells in the presence of blood flow. Applications of this technique may include rapid endothelialization of synthetic vascular grafts and dialysis fistulas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Remote control of cellular behaviour with magnetic nanoparticles
Dobson, J. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.39 · Cited by 528
Universal cell labelling with anionic magnetic nanoparticles
Wilhelm, C., & Gazeau, F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.016 · Cited by 343
Magnetic targeting for site-specific drug delivery: applications and clinical potential
Polyak, B., & Friedman, G. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240802662795 · Cited by 260
Polyak, B., Fishbein, I., Chorny, M., Alferiev, I., Williams, D., Yellen, B., Friedman, G., & Levy, R. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708338105 · Cited by 257
Metadata
- Authors
- Pislaru, S. V., Harbuzariu, A., Agarwal, G., Witt AAS CVT LATG, T., Gulati, R., Sandhu, N. P., Mueske AA, C., Kalra, M., Simari, R. D., & Sandhu, G. S.
- Venue
- Circulation
- Published
- 2006-07-04
- Volume
- 114
- Issue
- 1_supplement
- Pages
- I314-8
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2042643965
- Cited by
- 105
- References
- 0
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Forces Enable Rapid Endothelialization of Synthetic Vascular Grafts. https://app.cochat.ai/papers/10.1161/circulationaha.105.001446
- The paper
- Pislaru, S. V., Harbuzariu, A., Agarwal, G., Witt AAS CVT LATG, T., Gulati, R., Sandhu, N. P., Mueske AA, C., Kalra, M., Simari, R. D., & Sandhu, G. S. (2006). Magnetic Forces Enable Rapid Endothelialization of Synthetic Vascular Grafts. Circulation. https://doi.org/10.1161/circulationaha.105.001446
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.