CoChat

Is Blood Superior to Crystalloid Cardioplegia?: A Meta-Analysis of Randomized Clinical Trials

Guru, Veena, Omura, John, Alghamdi, Abdullah A., Weisel, Richard, Fremes, Stephen E. · 2006 · Circulation
Cited by 175

The DOI matches its Crossref record.

Abstract

Background— Many small, randomized, controlled trials have evaluated the effectiveness of blood as compared with crystalloid cardioplegia for myocardial protection during cardiac surgery. Blood cardioplegia provides a closer approximation to normal physiology, which may translate into measurable clinical benefits. This meta-analysis describes the effectiveness of blood cardioplegia in lowering adverse postoperative outcomes. Methods and Results— MEDLINE, EMBASE, and the Cochrane registry of controlled trials were searched for clinical trials. The search was restricted to peer-reviewed English language publications of randomized controlled trials that primarily compared blood and crystalloid cardioplegia in adult patients. Each trial was blindly assessed and abstracted by 2 reviewers. The primary outcomes were: low output syndrome (LOS), myocardial infarction (MI), and death. Surrogate outcomes included postoperative creatinine kinase MB (CKMB) increase. Random effects summary odds ratio (OR) for binary outcomes, and weighted mean difference for continuous outcomes were calculated. A total of 34 trials were included. The majority of trials were conducted in patients undergoing elective CABG surgery (n=18). The incidence of LOS was decreased significantly with blood cardioplegia (OR, 0.54; 95% confidence interval [CI], 0.34 to 0.84; P =0.006; 879 patients, 10 trials). The incidence of MI and death were similar between treatment groups (MI: OR, 0.78; 95% CI, 0.54 to 1.13; 4316 patients, 23 trials) (death: OR, 0.80; 95% CI, 0.46 to 1.40; 4022 patients, 17 trials). CKMB release after surgery at 24 hours was reduced with blood cardioplegia (5.9 U/L; 95% CI, 1.6 to 10.2; P =0.007; 821 patients, 7 trials). Conclusions— Blood cardioplegia provides superior myocardial protection as compared with crystalloid cardioplegia, including lower rates of LOS, and early CKMB increase, whereas the incidence of myocardial infarction and death are similar.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.001644

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Guru, V., Omura, J., Alghamdi, A. A., Weisel, R., & Fremes, S. E.
Venue
Circulation
Published
2006-07-04
Volume
114
Issue
1_supplement
Pages
I331-8
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2146056720
Cited by
175
References
0
FWCI
5.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Is Blood Superior to Crystalloid Cardioplegia?: A Meta-Analysis of Randomized Clinical Trials. https://app.cochat.ai/papers/10.1161/circulationaha.105.001644
The paper
Guru, V., Omura, J., Alghamdi, A. A., Weisel, R., & Fremes, S. E. (2006). Is Blood Superior to Crystalloid Cardioplegia?: A Meta-Analysis of Randomized Clinical Trials. Circulation. https://doi.org/10.1161/circulationaha.105.001644

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.