Background— Endocardial mapping of localized sources driving atrial fibrillation (AF) in humans has not been reported. Methods and Results— Fifty patients with AF organized by prior pulmonary vein and linear ablation were studied. AF was considered organized if mapping during AF showed irregular but discrete atrial complexes exhibiting consistent activation sequences for >75% of the time using a 20-pole catheter with 5 radiating spines covering 3.5-cm diameter or sequential conventional mapping. A site or region centrifugally activating the remaining atrial tissue defined a source. During AF with a cycle length of 211±32 ms, activation mapping identified 1 to 3 sources at the origin of atrial wavefronts in 38 patients (76%) predominantly in the left atrium, including the coronary sinus region. Electrograms at the earliest area varied from discrete centrifugal activation to an activity spanning 75% to 100% of the cycle length in 42% of cases, the latter indicating complex local conduction or a reentrant circuit. A gradient of cycle length (>20 ms) to the surrounding atrium was observed in 28%. Local radiofrequency ablation prolonged AF cycle length by 28±22 ms and either terminated AF or changed activation sequence to another organized rhythm. In 4 patients, the driving source was isolated, surrounded by the atrium in sinus rhythm, and still firing at high frequency (228±31 ms) either permanently or in bursts. Conclusions— AF associated with consistent atrial activation sequences after prior ablation emanates mostly from localized sources that can be mapped and ablated. Some sources harbor electrograms suggesting the presence of localized reentry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.546648

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 231

Metadata

Authors
Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L.-F., Jonsson, A., O’Neill, M. D., Bordachar, P., Reuter, S., Roudaut, R., Clémenty, J., & Jaïs, P.
Venue
Circulation
Published
2006-02-07
Volume
113
Issue
5
Pages
616-625
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2150710160
Cited by
231
References
0
FWCI
16.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. https://app.cochat.ai/papers/10.1161/circulationaha.105.546648
The paper
Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L.-F., Jonsson, A., O’Neill, M. D., Bordachar, P., Reuter, S., Roudaut, R., Clémenty, J., & Jaïs, P. (2006). Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. Circulation. https://doi.org/10.1161/circulationaha.105.546648

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.