The DOI matches its Crossref record.
Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation
Abstract
Background— Endocardial mapping of localized sources driving atrial fibrillation (AF) in humans has not been reported. Methods and Results— Fifty patients with AF organized by prior pulmonary vein and linear ablation were studied. AF was considered organized if mapping during AF showed irregular but discrete atrial complexes exhibiting consistent activation sequences for >75% of the time using a 20-pole catheter with 5 radiating spines covering 3.5-cm diameter or sequential conventional mapping. A site or region centrifugally activating the remaining atrial tissue defined a source. During AF with a cycle length of 211±32 ms, activation mapping identified 1 to 3 sources at the origin of atrial wavefronts in 38 patients (76%) predominantly in the left atrium, including the coronary sinus region. Electrograms at the earliest area varied from discrete centrifugal activation to an activity spanning 75% to 100% of the cycle length in 42% of cases, the latter indicating complex local conduction or a reentrant circuit. A gradient of cycle length (>20 ms) to the surrounding atrium was observed in 28%. Local radiofrequency ablation prolonged AF cycle length by 28±22 ms and either terminated AF or changed activation sequence to another organized rhythm. In 4 patients, the driving source was isolated, surrounded by the atrium in sinus rhythm, and still firing at high frequency (228±31 ms) either permanently or in bursts. Conclusions— AF associated with consistent atrial activation sequences after prior ablation emanates mostly from localized sources that can be mapped and ablated. Some sources harbor electrograms suggesting the presence of localized reentry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Metadata
- Authors
- Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L.-F., Jonsson, A., O’Neill, M. D., Bordachar, P., Reuter, S., Roudaut, R., Clémenty, J., & Jaïs, P.
- Venue
- Circulation
- Published
- 2006-02-07
- Volume
- 113
- Issue
- 5
- Pages
- 616-625
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2150710160
- Cited by
- 231
- References
- 0
- FWCI
- 16.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. https://app.cochat.ai/papers/10.1161/circulationaha.105.546648
- The paper
- Haïssaguerre, M., Hocini, M., Sanders, P., Takahashi, Y., Rotter, M., Sacher, F., Rostock, T., Hsu, L.-F., Jonsson, A., O’Neill, M. D., Bordachar, P., Reuter, S., Roudaut, R., Clémenty, J., & Jaïs, P. (2006). Localized Sources Maintaining Atrial Fibrillation Organized by Prior Ablation. Circulation. https://doi.org/10.1161/circulationaha.105.546648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.