Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 233

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations

Open access
Dong, Jun, Calkins, Hugh, Solomon, Stephen B., Lai, Shenghan, Dalal, Darshan, Lardo, Al, Brem, Erez, Preiss, Assaf, Berger, Ronald D., Halperin, Henry, Dickfeld, Timm·2006·Circulation

Abstract

Background— New ablation strategies for atrial fibrillation or nonidiopathic ventricular tachycardia are increasingly based on anatomic consideration and require the placement of ablation lesions at the correct anatomic locations. This study sought to evaluate the accuracy of the first clinically available image integration system for catheter ablation on 3-dimensional (3D) computed tomography (CT) images in real time. Methods and Results— After midline sternotomy, 2.3-mm CT fiducial markers were attached to the epicardial surface of each cardiac chamber in 9 mongrel dogs. Detailed 3D cardiac anatomy was reconstructed from contrast-enhanced, high-resolution CT images and registered to the electroanatomic maps of each cardiac chamber. To assess accuracy, targeted ablations were performed at each of the fiducial markers guided only by the reconstructed 3D images. At autopsy, the position error was 1.9±0.9 mm for the right atrium, 2.7±1.2 mm for the right ventricle, 1.8±1.0 mm for the left atrium, and 2.3±1.1 mm for the left ventricle. To evaluate the system’s guidance of more complex clinical ablation strategies, ablations of the cavotricuspid isthmus (n=4), fossa ovalis (n=4), and pulmonary veins (n=6) were performed, which resulted in position errors of 1.8±1.5, 2.2±1.3, and 2.1±1.2 mm, respectively. Retrospective analysis revealed that a combination of landmark registration and the target chamber surface registration resulted in <3 mm accuracy in all 4 cardiac chambers. Conclusions— Image integration with high-resolution 3D CT allows accurate placement of anatomically guided ablation lesions and can facilitate complex ablation strategies. This may provide significant advantages for anatomically based procedures such as ablation of atrial fibrillation and nonidiopathic ventricular tachycardia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.565200

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 233

Metadata

Authors
Dong, J., Calkins, H., Solomon, S. B., Lai, S., Dalal, D., Lardo, A., Brem, E., Preiss, A., Berger, R. D., Halperin, H., & Dickfeld, T.
Venue
Circulation
Published
2006-01-17
Volume
113
Issue
2
Pages
186-194
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2147373909
Cited by
233
References
1
FWCI
20.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations. https://app.cochat.ai/papers/10.1161/circulationaha.105.565200
The paper
Dong, J., Calkins, H., Solomon, S. B., Lai, S., Dalal, D., Lardo, A., Brem, E., Preiss, A., Berger, R. D., Halperin, H., & Dickfeld, T. (2006). Integrated Electroanatomic Mapping With Three-Dimensional Computed Tomographic Images for Real-Time Guided Ablations. Circulation. https://doi.org/10.1161/circulationaha.105.565200

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.