Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record.

Randomized Trial of a Nonpolymer-Based Rapamycin-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent for the Reduction of Late Lumen Loss

Mehilli, Julinda, Kastrati, Adnan, Wessely, Rainer, Dibra, Alban, Hausleiter, Jörg, Jaschke, Birgit, Dirschinger, Josef, Schömig, Albert·2006·Circulation

Abstract

Background— Although drug-eluting stents (DESs) constitute a major achievement in preventing restenosis, concerns remain regarding the increased inflammatory and thrombogenic responses associated with the polymers used. Recently, we showed that a nonpolymer on-site coating with rapamycin not only is feasible and safe but also leads to a dose-dependent reduction in restenosis. Methods and Results— To assess whether polymer-free stents coated on-site with 2% rapamycin solution are inferior to polymer-based paclitaxel-eluting stents for the prevention of restenosis, we randomly assigned a total of 450 patients with de novo lesions in native coronary vessels, excluding the left main trunk, to either the polymer-free, rapamycin-coated Yukon DES (rapamycin stent) or the polymer-based, paclitaxel-eluting Taxus stent (paclitaxel stent). The primary end point was in-stent late lumen loss. Secondary end points were angiographic restenosis and target lesion revascularization. The study was designed to test the noninferiority of the rapamycin stent compared with the paclitaxel stent with respect to late lumen loss according to a noninferiority margin of 0.13 mm. Follow-up angiography was completed in 81% of the patients. The mean difference in in-stent late lumen loss between the rapamycin-stent group and the paclitaxel-stent group was 0.002 mm, and the upper limit of the 1-sided 95% confidence interval was 0.10 mm ( P =0.02 from test for noninferiority). No significant differences were observed regarding angiographic restenosis rates (14.2% with the rapamycin stent and 15.5% with the paclitaxel stent) and target lesion revascularization rates due to restenosis (9.3% in both groups). Conclusions— The polymer-free, rapamycin-coated stent has an antirestenotic effect that is not inferior to that observed with the polymer-based paclitaxel-eluting stent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.575977

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 179

Metadata

Authors
Mehilli, J., Kastrati, A., Wessely, R., Dibra, A., Hausleiter, J., Jaschke, B., Dirschinger, J., & Schömig, A.
Venue
Circulation
Published
2006-01-17
Volume
113
Issue
2
Pages
273-279
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2095508172
Cited by
179
References
0
FWCI
15.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Randomized Trial of a Nonpolymer-Based Rapamycin-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent for the Reduction of Late Lumen Loss. https://app.cochat.ai/papers/10.1161/circulationaha.105.575977
The paper
Mehilli, J., Kastrati, A., Wessely, R., Dibra, A., Hausleiter, J., Jaschke, B., Dirschinger, J., & Schömig, A. (2006). Randomized Trial of a Nonpolymer-Based Rapamycin-Eluting Stent Versus a Polymer-Based Paclitaxel-Eluting Stent for the Reduction of Late Lumen Loss. Circulation. https://doi.org/10.1161/circulationaha.105.575977

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.