Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Cost-Effectiveness of Defibrillator Therapy or Amiodarone in Chronic Stable Heart Failure: Results From the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)

Open access
Mark, Daniel B., Nelson, Charlotte L., Anstrom, Kevin J., Al-Khatib, Sana M., Tsiatis, Anastasios A., Cowper, Patricia A., Clapp-Channing, Nancy E., Davidson-Ray, Linda, Poole, Jeanne E., Johnson, George, Anderson, Jill, Lee, Kerry L., Bardy, Gust H.·2006·Circulation

Abstract

Background— In the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), implantable cardioverter-defibrillator (ICD) therapy significantly reduced all-cause mortality rates compared with medical therapy alone in patients with stable, moderately symptomatic heart failure, whereas amiodarone had no benefit on mortality rates. We examined long-term economic implications of these results. Methods and Results— Medical costs were estimated by using hospital billing data and the Medicare Fee Schedule. Our base case cost-effectiveness analysis used empirical clinical and cost data to estimate the lifetime incremental cost of saving an extra life-year with ICD therapy relative to medical therapy alone. At 5 years, the amiodarone arm had a survival rate equivalent to that of the placebo arm and higher costs than the placebo arm. For ICD relative to medical therapy alone, the base case lifetime cost-effectiveness and cost-utility ratios (discounted at 3%) were $38 389 per life-year saved (LYS) and $41 530 per quality-adjusted LYS, respectively. A cost-effectiveness ratio <$100 000 was obtained in 99% of 1000 bootstrap repetitions. The cost-effectiveness ratio was sensitive to the amount of extrapolation beyond the empirical 5-year trial data: $127 503 per LYS at 5 years, $88 657 per LYS at 8 years, and $58 510 per LYS at 12 years. Because of a significant interaction between ICD treatment and New York Heart Association class, the cost-effectiveness ratio was $29 872 per LYS for class II, whereas there was incremental cost but no incremental benefit in class III. Conclusions— Prophylactic use of single-lead, shock-only ICD therapy is economically attractive in patients with stable, moderately symptomatic heart failure with an ejection fraction ≤35%, particularly those in NYHA class II, as long as the benefits of ICD therapy observed in the SCD-HeFT persist for at least 8 years.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.581884

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 265

Metadata

Authors
Mark, D. B., Nelson, C. L., Anstrom, K. J., Al-Khatib, S. M., Tsiatis, A. A., Cowper, P. A., Clapp-Channing, N. E., Davidson-Ray, L., Poole, J. E., Johnson, G., Anderson, J., Lee, K. L., & Bardy, G. H.
Venue
Circulation
Published
2006-07-11
Volume
114
Issue
2
Pages
135-142
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2157850567
Cited by
265
References
1
FWCI
22.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.