CoChat

Creation of Engineered Cardiac Tissue In Vitro From Mouse Embryonic Stem Cells

Guo, Xi-Min, Zhao, Yun-Shan, Chang, Hai-Xia, Wang, Chang-Yong, E, Ling-Ling, Zhang, Xiao-Ai, Duan, Cui-Mi, Dong, Ling-Zhi, Jiang, Hong, Li, Jing, Song, Ying, Yang, Xiangzhong (Jerry) · 2006 · Circulation
Cited by 150

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background— Embryonic stem (ES) cells can terminally differentiate into all types of somatic cells and are considered a promising source of seed cells for tissue engineering. However, despite recent progress in in vitro differentiation and in vivo transplantation methodologies of ES cells, to date, no one has succeeded in using ES cells in tissue engineering for generation of somatic tissues in vitro for potential transplantation therapy. Methods and Results— ES-D3 cells were cultured in a slow-turning lateral vessel for mass production of embryoid bodies. The embryoid bodies were then induced to differentiate into cardiomyocytes in a medium supplemented with 1% ascorbic acid. The ES cell–derived cardiomyocytes were then enriched by Percoll gradient centrifugation. The enriched cardiomyocytes were mixed with liquid type I collagen supplemented with Matrigel to construct engineered cardiac tissue (ECT). After in vitro stretching for 7 days, the ECT can beat synchronously and respond to physical and pharmaceutical stimulation. Histological, immunohistochemical, and transmission electron microscopic studies further indicate that the ECTs both structurally and functionally resemble neonatal native cardiac muscle. Markers related to undifferentiated ES cell contamination were not found in reverse transcriptase–polymerase chain reaction analysis of the Percoll-enriched cardiomyocytes. No teratoma formation was observed in the ECTs implanted subcutaneously in nude mice for 4 weeks. Conclusions— ES cells can be used as a source of seed cells for cardiac tissue engineering. Additional work remains to demonstrate engraftment of the engineered heart tissue in the case of cardiac defects and its functional integrity within the host’s remaining healthy cardiac tissue.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.583039

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 150

Metadata

Authors
Guo, X.-M., Zhao, Y.-S., Chang, H.-X., Wang, C.-Y., E, L.-L., Zhang, X.-A., Duan, C.-M., Dong, L.-Z., Jiang, H., Li, J., Song, Y., & Yang, X. (.
Venue
Circulation
Published
2006-05-09
Volume
113
Issue
18
Pages
2229-2237
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2116953529
Cited by
150
References
3
FWCI
5.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Creation of Engineered Cardiac Tissue In Vitro From Mouse Embryonic Stem Cells. https://app.cochat.ai/papers/10.1161/circulationaha.105.583039
The paper
Guo, X.-M., Zhao, Y.-S., Chang, H.-X., Wang, C.-Y., E, L.-L., Zhang, X.-A., Duan, C.-M., Dong, L.-Z., Jiang, H., Li, J., Song, Y., & Yang, X. (. (2006). Creation of Engineered Cardiac Tissue In Vitro From Mouse Embryonic Stem Cells. Circulation. https://doi.org/10.1161/circulationaha.105.583039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.