Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 200

The DOI matches its Crossref record.

A Tailored Approach to Catheter Ablation of Paroxysmal Atrial Fibrillation

Open access
Oral, Hakan, Chugh, Aman, Good, Eric, Sankaran, Sundar, Reich, Stephen S., Igic, Petar, Elmouchi, Darryl, Tschopp, David, Crawford, Thomas, Dey, Sujoya, Wimmer, Alan, Lemola, Kristina, Jongnarangsin, Krit, Bogun, Frank, Pelosi, Frank, Morady, Fred · 2006 · Circulation

Abstract

Background— Because the genesis of atrial fibrillation (AF) is multifactorial and variable, an ablation strategy that involves pulmonary vein isolation and/or a particular set of ablation lines may not be equally effective or efficient in all patients with AF. A tailored strategy that targets initiators and drivers of AF is a possible alternative to a standardized lesion set. Methods and Results— Catheter ablation was performed in 153 consecutive patients (mean age, 56±11 years) with symptomatic paroxysmal AF with the use of an 8-mm tip radiofrequency ablation catheter. The esophagus was visualized with barium. The pulmonary veins and left atrium were mapped during spontaneous or induced AF. Arrhythmogenic pulmonary veins were isolated or encircled. If AF was still present or inducible, complex electrograms in the left atrium, coronary sinus, and superior vena cava were targeted for ablation. The end point of ablation was absence of frequent atrial ectopy and spontaneous AF during isoproterenol infusion and noninducibility of AF. Routine energy applications near the esophagus were avoided. During follow-up, left atrial flutter developed in 19% of patients and was still present in 10% at >12 weeks of follow-up. A repeat ablation procedure was performed in 18% of patients. During a mean follow-up of 11±4 months, 77% of patients were free from AF and/or atrial flutter without antiarrhythmic drug therapy. Pericardial tamponade or transient neurological events occurred in 2% of procedures. Conclusions— A tailored ablation strategy that only targets triggers and drivers of AF is feasible and eliminates paroxysmal AF in ≈80% of patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.601898

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Oral, H., Chugh, A., Good, E., Sankaran, S., Reich, S. S., Igic, P., Elmouchi, D., Tschopp, D., Crawford, T., Dey, S., Wimmer, A., Lemola, K., Jongnarangsin, K., Bogun, F., Pelosi, F., & Morady, F.
Venue
Circulation
Published
2006-04-18
Volume
113
Issue
15
Pages
1824-1831
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2131026238
Cited by
200
References
0
FWCI
24.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Tailored Approach to Catheter Ablation of Paroxysmal Atrial Fibrillation. https://app.cochat.ai/papers/10.1161/circulationaha.105.601898
The paper
Oral, H., Chugh, A., Good, E., Sankaran, S., Reich, S. S., Igic, P., Elmouchi, D., Tschopp, D., Crawford, T., Dey, S., Wimmer, A., Lemola, K., Jongnarangsin, K., Bogun, F., Pelosi, F., & Morady, F. (2006). A Tailored Approach to Catheter Ablation of Paroxysmal Atrial Fibrillation. Circulation. https://doi.org/10.1161/circulationaha.105.601898