Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 252

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Heart Failure During Cardiac Pacing

Open access
Sweeney, Michael O., Hellkamp, Anne S.·2006·Circulation

Abstract

Background— Right ventricular apical (RVA) pacing creates abnormal left ventricular contraction, hypertrophy, and reduced pump function. The adverse effects of ventricular desynchronization may explain the association of RVA pacing with an increased risk of heart failure hospitalization (HFH) in clinical trials. Methods and Results— Baseline and postimplantation variables were used to predict HFH in the Mode Selection Trial, a 2010-patient, 6-year trial of dual-chamber (DDDR) versus ventricular (VVIR) pacing in sinus node dysfunction. A Cox model showed that New York Heart Association (NYHA) class at baseline and follow-up predicted HFH (hazard ratio [HR], 3.99; 95% confidence interval [CI], 2.74–5.79 for NYHA class III/IV and HR, 2.17; 95% CI, 1.54–3.04 for NYHA class II versus class I); other predictors were heart failure (HR, 2.30; 95% CI, 1.70–3.11), atrioventricular (AV) block (HR, 1.48; 95% CI, 1.11–1.97), and myocardial infarction (MI)(HR, 1.37; 95% CI, 1.00–1.86). Postimplantation predictors were VVIR cumulative percent ventricular pacing (Cum%VP) >80 (HR, 3.58; 95% CI, 1.72–7.45), DDDR Cum%VP >40 or VVIR Cum%VP ≤80 (HR, 1.81; 95% CI, 0.94–3.50) versus DDDR Cum%VP ≤40; whether QRS duration (QRSd) was paced or spontaneous (HR, 2.21; 95% CI, 1.39–3.54; spontaneous versus paced); and drugs for atrial fibrillation (HR, 1.60; 95% CI, 1.19–2.15). Low baseline ejection fraction (EF) and postimplantation RVA-paced or spontaneous QRSd predicted HFH; the increased risk with QRSd was steeper for normal versus low EF (HR, 1.18; 95% CI, 1.11–1.27; versus HR, 1.08; 95% CI, 1.01–1.15; for a 10-ms increase); at a QRSd of ≈200 ms, normal- and low-EF patients had equivalent risk. HFH risk nearly doubled when VVIR Cum%VP was ≤80 or DDDR Cum%VP was >40 versus DDDR Cum%VP ≤40 and was additive with other risk factors. Conclusions— Differences in HFH risk can be explained by interactions between substrate (atrial fibrillation, AV conduction, heart failure, MI, EF) and pacing promoters (ventricular desynchronization-paced QRSd and Cum%VP, and AV desynchronization-pacing mode). Management of RVA pacing is important for reducing the risk of HFH, particularly among patients with low EF and heart failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.608356

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 252

Metadata

Authors
Sweeney, M. O., & Hellkamp, A. S.
Venue
Circulation
Published
2006-05-02
Volume
113
Issue
17
Pages
2082-2088
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2042259717
Cited by
252
References
3
FWCI
12.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart Failure During Cardiac Pacing. https://app.cochat.ai/papers/10.1161/circulationaha.105.608356
The paper
Sweeney, M. O., & Hellkamp, A. S. (2006). Heart Failure During Cardiac Pacing. Circulation. https://doi.org/10.1161/circulationaha.105.608356

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.