The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Effect of Amiodarone and Sotalol on Ventricular Defibrillation Threshold: The Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC) Trial
Open accessAbstract
Background— Many patients with implanted cardioverter defibrillators (ICDs) receive adjunctive antiarrhythmic drug therapy, most commonly amiodarone or sotalol. The effects of these drugs on defibrillation energy requirements have not been previously assessed in a randomized controlled trial. Methods and Results— The Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC) trial was a randomized clinical trial evaluating the efficacy of amiodarone plus β-blocker and sotalol versus β-blocker alone for reduction of ICD shocks. Within OPTIC, a prospectively designed substudy evaluated the effects of the 3 treatment arms on defibrillation energy requirements. Defibrillation thresholds (DFTs) were measured (binary step-down protocol) at baseline and again after 8 to 12 weeks of therapy in 94 patients, of whom 29 were randomized to receive β-blocker therapy (control group), 35 to amiodarone plus β-blocker, and 30 to sotalol. In the control group, the mean DFT decreased from 8.77±5.15 J at baseline to 7.13±3.43 J ( P =0.027); in the amiodarone group, DFT increased from 8.53±4.29 to 9.82±5.84 J ( P =0.091). In the sotalol group, DFT decreased from 8.09±4.81 to 7.20±5.30 J ( P =0.21). DFT changes in the β-blocker and the amiodarone group were significantly different ( P =0.006). In all patients, adequate safety margins for defibrillation were maintained. No clinical variable predicted baseline DFT or changes in DFT on therapy. Conclusion— Although amiodarone increased DFT, the effect size with modern ICD systems is very small. Therefore, DFT reassessment after the institution of antiarrhythmic drug therapy with amiodarone or sotalol is not routinely required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Data on the impact of antiarrhythmic drugs, used for atrial and ventricular arrhythmias, as well, on the defibrillation threshold are variable, but 1 randomized study 76 has suggested that amiodarone may increase, whereas sotalol and β-blockers decrease, the defibrillation threshold.”
From Managing with pacemakers and implantable cardioverter defibrillators (2013) · cites this paper as [76]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Prophylactic Defibrillator Implantation in Patients with Nonischemic Dilated Cardiomyopathy
Kadish, A. H., Dyer, A. R., Daubert, J. P., Quigg, R. J., Estes, N. A. M., Anderson, K. P., Calkins, H. G., Hoch, D., Goldberger, J. J., Shalaby, A. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033088 · Cited by 2,078
Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials
Connolly, S. J. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2476 · Cited by 1,138
Self-citationConnolly, S. J. (2006) · JAMA · doi:10.1001/jama.295.2.165 · Cited by 788
Self-citationDesai, A. S., Fang, J. C., Maisel, W. H., & Baughman, K. L. (2004) · JAMA · doi:10.1001/jama.292.23.2874 · Cited by 403
Russo, A. M., Sauer, W. H., Gerstenfeld, E. P., Hsia, H. H., Lin, D., Cooper, J. M., Dixit, S., Verdino, R. J., Nayak, H. M., Callans, D. J., et al. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.01.015 · Cited by 191
Epstein, A. E., Ellenbogen, K. A., Kirk, K. A., Kay, G. N., Dailey, S. M., & Plumb, V. J. (1992) · Circulation · doi:10.1161/01.cir.86.4.1206 · Cited by 174
Effects of chronic amiodarone therapy on defibrillation threshold
Jung, W., MANZ, M., Pizzulli, L., Pfeiffer, D., & Lüderitz, B. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)90354-2 · Cited by 138
Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation
Gold, M. R., Higgins, S. L., Klein, R. C., Gilliam, F. R., Kopelman, H. A., Hessen, S. E., PAYNE, J. P., Strickberger, S. A., Breiter, D. J., & Hahn, S. J. (2002) · Circulation · doi:10.1161/01.cir.0000015508.59749.f5 · Cited by 136
Cited by
Sorted by citations
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Authors Task Force Members, Priori, S. G., Blomström‐Lundqvist, C., Mazzanti, A., Blom, N. A., Borggrefe, M., Camm, J. A., Elliot, P. M., Fitzsimons, D., Hatala, R., et al. (2015) · EP Europace · doi:10.1093/europace/euv319 · Cited by 1,671
Vassallo, P., & Trohman, R. G. (2007) · JAMA · doi:10.1001/jama.298.11.1312 · Cited by 449
Healey, J. S., Hohnloser, S. H., Glikson, M., Neuzner, J., Mabo, P., Viñolas, X., Kautzner, J., O’Hara, G. E., VanErven, L., Gadler, F., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61903-6 · Cited by 244
Self-citationDan, G., Martínez‐Rubio, A., Agewall, S., Boriani, G., Borggrefe, M., Gaïta, F., Gelder, I. C. V., Görenek, B., Kaski, J. C., Kjeldsen, K. P., et al. (2018) · EP Europace · doi:10.1093/europace/eux373 · Cited by 247
Gopinathannair, R., Cornwell, W. K., Dukes, J. W., Ellis, C. R., Hickey, K. T., Joglar, J. A., Pagani, F. D., Roukoz, H., Slaughter, M. S., & Patton, K. K. (2019) · Circulation · doi:10.1161/cir.0000000000000673 · Cited by 175
The Dilemma of ICD Implant Testing
Swerdlow, C. D., Russo, A. M., & DeGroot, P. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00730.x · Cited by 154
Electrical Storm in Patients with an Implanted Defibrillator: A Matter of Definition
Israel, C. W., & Barold, S. S. (2007) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00187.x · Cited by 127
Self-citationPriori, S. G., Blomström‐Lundqvist, C., Mazzanti, A., Blom, N. A., Borggrefe, M., Camm, A. J., Elliot, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2016) · Revista Española de Cardiología · doi:10.1016/j.recesp.2016.01.001 · Cited by 138
Koster, R. W., Walker, R. G., & Chapman, F. W. (2008) · Resuscitation · doi:10.1016/j.resuscitation.2008.03.231 · Cited by 120
Camm, A. J., & Bounameaux, H. (2011) · Drugs · doi:10.2165/11595540-000000000-00000 · Cited by 107
I Diretriz Latino-Americana para o Diagnóstico e Tratamento da Cardiopatia Chagásica
Castro, I., de Andrade, J. P., de Paola, Â. A. V., Vilas‐Boas, F., de Oliveira, G. M. M., Marin‐Neto, J. A., Chagas, A. C. P., Rocha, E. A. V., de Oliveira, G. M. M., Zimerman, L. I., et al. (2011) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2011001600001 · Cited by 103
Merino, J. L., Tamargo, J. L., Blomström‐Lundqvist, C., Boriani, G., Crijns, H. J. G. M., Dobrev, D., Goette, A., Hohnloser, S. H., Naccarelli, G. V., Reiffel, J. A., et al. (2025) · EP Europace · doi:10.1093/europace/euaf076 · Cited by 112
Self-citationManegold, J. C., Israel, C. W., Ehrlich, J. R., Duray, G. Z., Pajitnev, D., Wegener, F., & Hohnloser, S. H. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm211 · Cited by 86
Self-citationBAKER, A. J., Rhind, S. G., Morrison, L. J., Black, S. E., Crnko, N. T., Shek, P. N., & Rizoli, S. B. (2009) · Journal of Neurotrauma · doi:10.1089/neu.2008.0868 · Cited by 83
Frommeyer, G., Milberg, P., Witte, P., Stypmann, J., Koopmann, M., Lücke, M., Osada, N., BREITHARDT, G. E., Fehr, M., & Eckardt, L. (2011) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfr107 · Cited by 69
Abuissa, H. S., Roshan, J., Lim, B., & Asirvatham, S. J. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2009.01673.x · Cited by 55
Amiodarone versus other pharmacological interventions for prevention of sudden cardiac death
Claro, J. C., Cândia, R., Gabriel Rada, G., Baraona, F., Larrondo, F., & Luz María Letelier, S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008093.pub2 · Cited by 53
Fischer, A., Ousdigian, K. T., Johnson, J. W., Gillberg, J. M., & Wilkoff, B. L. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.08.005 · Cited by 53
Is Defibrillation Testing Still Necessary? A Decision Analysis and Markov Model
Gula, L. J., Massel, D. R., Krahn, A. D., Yee, R. K., Skanes, A. C., & Klein, G. J. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.01095.x · Cited by 51
Um, K. J., McIntyre, W. F., Healey, J. S., Mendoza, P. A., Koziarz, A., Amit, G., Chu, V. A., Whitlock, R. P., & Belley‐Côté, E. P. (2018) · EP Europace · doi:10.1093/europace/euy310 · Cited by 56
Defibrillation Testing at the Time of ICD Insertion: An Analysis From the Ontario ICD Registry
Healey, J. S., BIRNIE, D. H., Lee, D. S., Krahn, A. D., Crystal, E., Simpson, C., Dorian, P., Chen, Z., CAMERON, D. A., Verma, A., et al. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01850.x · Cited by 47
Self-citationEffect of Drugs on Defibrillation Capacity
Dopp, A. L., Miller, J. M., & Tisdale, J. E. (2008) · Drugs · doi:10.2165/00003495-200868050-00004 · Cited by 48
LEE, W., Tay, A., SUBBIAH, R. N., WALKER, B. D., Kuchar, D. L., Muthiah, K., Macdonald, P. S., KEOGH, A. M., Kotlyar, E., Jabbour, A., et al. (2015) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12654 · Cited by 42
Singh, S. N., Tang, X. C., Reda, D. J., & Singh, B. N. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.10.036 · Cited by 43
Beta-blockers in cardiac arrhythmias–Clinical pharmacologist’s point of view
Wołowiec, Ł., Grześk, G., Osiak, J., Wijata, A., Mędlewska, M., Gaborek, P., Banach, J., Wołowiec, A., & Głowacka, M. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.1043714 · Cited by 38
Role of antiarrhythmic drugs in patients with implantable cardioverter defibrillators
Herendael, H. V., Pintér, A., Ahmad, K., Korley, V. J., Mangat, I., & Dorian, P. (2010) · EP Europace · doi:10.1093/europace/euq073 · Cited by 38
Self-citationManaging with pacemakers and implantable cardioverter defibrillators
Lampert, R. (2013) · Circulation · doi:10.1161/circulationaha.113.001555 · Cited by 34
Rudic, B., Tülümen, E., Fastenrath, F., Akın, İ., Borggrefe, M., & Kuschyk, J. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.10.024 · Cited by 34
Healey, J. S., Hohnloser, S. H., Glikson, M., NEUZNER, J., Viñolas, X., Mabo, P., Kautzner, J., O’Hara, G. E., Erven, L. V., Gadler, F., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.05.007 · Cited by 31
Self-citationImplantable cardioverter-defibrillator shock prevention does not reduce mortality: A systemic review
Ha, A. H., Ham, I., Nair, G. M., Connolly, S. J., Dorian, P., Morillo, C. A., & Healey, J. S. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.08.032 · Cited by 31
Self-citationInactivation of human glutamate dehydrogenase by aluminum
Yang, S.-J., Huh, J. W., Lee, J. E., Choi, S. Y., Kim, T. U., & Cho, S.-W. (2003) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-003-3298-y · Cited by 29
Delacrétaz, E., Brenner, R., Schaumann, A., Eckardt, L., Willems, S., Pitschner, H.-F., Kautzner, J., Schumacher, B., HANSEN, P. S., & Kück, K. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12073 · Cited by 26
Verma, A., Kaplan, A. J., Sarak, B., Oosthuizen, R., Beardsall, M., Higgenbottam, J., Wulffhart, Z. A., & Khaykin, Y. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9511-7 · Cited by 26
Liang, J. J., Yang, W. P., Santangeli, P., Schaller, R. D., Supple, G. E., Hutchinson, M. D., Garcia, F. C., Lin, D., Dixit, S., Epstein, A. E., et al. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.11.005 · Cited by 25
Kroll, M. W., & SCHWAB, J. O. (2010) · Fundamental and Clinical Pharmacology · doi:10.1111/j.1472-8206.2010.00848.x · Cited by 24
Flecainide How and When: A Practical Guide in Supraventricular Arrhythmias
Lavalle, C., Magnocavallo, M., Straito, M., Santini, L., Forleo, G. B., Grimaldi, M., Badagliacca, R., Lanata, L., & Ricci, R. P. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10071456 · Cited by 24
Is Defibrillation Testing Necessary for Implantable Transvenous Defibrillators?
Russo, A. M., & Chung, M. K. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000371 · Cited by 23
Ventricular arrhythmias in nonischemic cardiomyopathy
Chung, F., Lin, C., Lin, Y., Chang, S., Lo, L., Hu, Y., Tuan, T., Chao, T., Liao, J., Chang, Y., et al. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12028 · Cited by 23
Salcido, D. D., Schmicker, R. H., Kime, N. A., Buick, J. E., Cheskes, S., Grunau, B. E., Zellner, S., Zive, D. M., Aufderheide, T. P., Koller, A. C., et al. (2018) · Resuscitation · doi:10.1016/j.resuscitation.2018.05.028 · Cited by 23
Kpaeyeh, J. A., & Wharton, J. M. (2016) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2016.02.007 · Cited by 24
The Effect of Dofetilide on Ventricular Defibrillation Thresholds
Simón, R., Sturdivant, J. L., Leman, R. B., Wharton, J. M., & Gold, M. R. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2009.02172.x · Cited by 21
Outcome of direct current cardioversion for atrial arrhythmia in adult Fontan patients
Egbe, A. C., Connolly, H. M., Niaz, T., & McLeod, C. J. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.01.209 · Cited by 20
Sánchez-Muñoz, J.-J., Rojo‐Álvarez, J. L., Garcı́a-Alberola, A., Everss, E., Alonso‐Atienza, F., Ortiz, M., Martı́nez, J. A., Ramos, J., & Valdés‐Chávarri, M. (2008) · EP Europace · doi:10.1093/europace/eun366 · Cited by 20
Intravenous Sotalol - Reintroducing a Forgotten Agent to the Electrophysiology Therapeutic Arsenal
Batul, S. A., & Gopinathannair, R. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1499 · Cited by 19
Antiarrhythmic Drug Therapy to Avoid Implantable Cardioverter Defibrillator Shocks
Abboud, J., & Ehrlich, J. R. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.10.2 · Cited by 19
Keane, D., AWEH, N., HYNES, B., Sheahan, R. G., Cripps, T., Bashir, Y., Zaidi, A. M., Fahy, G. J., LOWE, M. D., DOHERTY, P., et al. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00718.x · Cited by 18
Should Catheter Ablation be the Preferred Therapy for Reducing ICD Shocks?
Kück, K. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.896571 · Cited by 18
Electrophysiologic Considerations After Sudden Cardiac Arrest
Suryanarayana, P. G., Garza, H.-H. K., Klewer, J., & Hutchinson, M. D. (2018) · Current Cardiology Reviews · doi:10.2174/1573403x14666180507164443 · Cited by 19
Antiarrhythmic Drugs and Strategies
Opie, L. H., Dimarco, J., & Gersh, B. J. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4160-6158-8.50013-7 · Cited by 16
Gopinathannair, R., Pothineni, N. V. K., Trivedi, J. R., Roukoz, H., Cowger, J. A., Ahmed, M. M., Bhan, A., Ravichandran, A. K., Bhat, G., Al‐Ahmad, A., et al. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.023762 · Cited by 15
Antiarrhythmic drugs and strategies
Nattel, S., Gersh, B. J., & Opie, L. H. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-3322-4.00017-x · Cited by 15
Mollerus, M. E., Lipinski, M., & Munger, T. M. (2008) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-008-9254-x · Cited by 15
Is Defibrillation Testing Necessary for Implantable Transvenous Defibrillators?
Healey, J. S., & Brambatti, M. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000373 · Cited by 14
Deneke, T., Borggrefe, M., Hindricks, G., Kirchhof, P. F., Kück, K., Stellbrink, C., & Eckardt, L. (2017) · Der Kardiologe · doi:10.1007/s12181-016-0115-z · Cited by 15
Should Catheter Ablation be the Preferred Therapy for Reducing ICD Shocks?
Patel, C., Yan, G., Kocovic, D. Z., & Kowey, P. R. (2009) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.893628 · Cited by 13
Israel, C. W., & Manegold, J. C. (2014) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-014-0321-y · Cited by 14
Self-citationManagement of Ventricular Tachycardia in Heart Failure
Baher, A. A., & Valderrábano, M. (2013) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-9-1-20 · Cited by 12
Droogan, C., Patel, C., Yan, G.-X., & Kowey, P. R. (2011) · Heart Failure Clinics · doi:10.1016/j.hfc.2010.12.003 · Cited by 10
Załucka, L., Świerżyńska, E., Orczykowski, M., Dutkowski, K., Szymański, J., Kuriata, J., Dąbrowski, R., Kołsut, P., Szumowski, Ł. J., & Sterlinski, M. M. (2024) · Sensors · doi:10.3390/s24041124 · Cited by 10
Management of high defibrillation threshold
Uyguanco, E. R., Berger, A., Budzikowski, A. S., Gunsburg, M. Y., & Kassotis, J. (2008) · Expert Review of Cardiovascular Therapy · doi:10.1586/14779072.6.9.1237 · Cited by 10
Implantable cardioverter defibrillator with and without defibrillation threshold testing.
Codner, P., Nevzorov, R., Kusniec, J., Haim, M., Shohat‐Zabarski, R., & Strasberg, B. (2012) · PubMed · Cited by 10
Follow-Up Defibrillator Testing for Antiarrhythmic Drugs
Wood, M. A., & Ellenbogen, K. A. (2006) · Circulation · doi:10.1161/circulationaha.106.637397 · Cited by 10
How to Manage a High Defibrillation Threshold in ICD Patients: and Does it Really Matter?
Matassini, M. V., & Healey, J. S. (2013) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-013-0244-7 · Cited by 9
Borne, R. T., Randolph, T. C., Wang, Y., Curtis, J. P., Peterson, P. N., Masoudi, F. A., Sandhu, A., Zipse, M. M., Thomas, K. L., Kutyifa, V., et al. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.13553 · Cited by 9
Problems with Implantable Cardiac Device Therapy
Kowalski, M., Huizar, J. F., Kaszala, K., & Wood, M. A. (2008) · Cardiology Clinics · doi:10.1016/j.ccl.2008.03.012 · Cited by 9
Treating arrhythmias: an expert opinion
Dagres, N., Sommer, P., ANASTASIOU‐NANA, M. I., & Hindricks, G. (2011) · Expert Opinion on Pharmacotherapy · doi:10.1517/14656566.2011.555397 · Cited by 9
Faheem, O., Padala, A., Kluger, J., ZWEIBEL, S. L., & Clyne, C. A. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02726.x · Cited by 9
Gomes, J. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-45066-3_22 · Cited by 9
Khan, U., Khlidj, Y., Ibrahim, A. A., Amin, A. M., Rakab, M. S., AlBarakat, M. M., Khan, M. H., Majeed, Z., Imran, M., Ali, J., et al. (2025) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2025.03.004 · Cited by 8
Defibrillation testing of the implantable cardioverter defibrillator: when, how, and by whom?
Pires, L. A. (2007) · PubMed Central · Cited by 8
Is Defibrillation Testing Necessary?
Russo, A. M., & Chung, M. K. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2014.01.003 · Cited by 8
Induction by direct current pulse versus 50-Hz pacing on ventricular fibrillation and defibrillation
Lim, H. S., Flannigan, S., & Marshall, H. J. (2010) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-010-9486-4 · Cited by 8
Neuzner, J., Hohnloser, S. H., Kutyifa, V., Glikson, M., Dietze, T., Mabo, P., Viñolas, X., Kautzner, J., O’Hara, G. E., Lawo, T., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13943 · Cited by 8
Self-citationChakarov, I., Mueller, J., Ene, E., Berkovitz, A., Sonne, K., Nentwich, K., Schupp, T., Behnes, M., & Deneke, T. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11144000 · Cited by 9
Sp, G., Kostyukevich, M. V., Laiovich, L. I., Mironov, N. Y., Миронова, Н. А., Utsumueva, M. D., Khusyainova, D. R., Шлевков, Н. Б., Bazarov, B. C., Азизов, В. А., et al. (2022) · Eurasian heart journal · doi:10.38109/2225-1685-2022-4-6-67 · Cited by 10
Effects of Anti-arrhythmic Drugs for Pacing Threshold and Defibrillation Threshold
Ishikawa, T. (2011) · Journal of Arrhythmia · doi:10.1016/s1880-4276(11)80052-9 · Cited by 8
Atrial Selective Effect of Amiodarone to Increase Threshold of Excitation
GRANDE, J. M., Grande, Á., Molina, M., NOVO, C., & Cabestrero, F. (2011) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2011.03272.x · Cited by 8
Ursaru, A. M., Costache, I. I., Petriş, A. O., & Tesloianu, D. N. (2021) · Biomedicines · doi:10.3390/biomedicines9111595 · Cited by 7
Lacoste, J. L., Avalon, J. C., Ludhwani, D., Conte, J., Perkowski, G., Patel, B., Courser, A., & Balla, S. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.06.121 · Cited by 7
Okishige, K., Uehara, H., Miyagi, N., Nakamura, K., Azegami, K., Wakimoto, H., Ohba, K., Hirao, K., Shimabukuro, M., & Isobe, M. (2007) · Circulation Journal · doi:10.1253/circj.72.76 · Cited by 7
Single-coil Versus Dual-coil ICD Lead Shock Efficacy in a Large ICD Registry
Ellis, C. R., & Hurt, J. T. (2012) · Cited by 7
Portadores de CDI com limiar de desfibrilação elevado: evolução clínica e alternativas terapêuticas
de Lima, C. E. B., Filho, M. M., Silva, R. T., Tamaki, W. T., de Oliveira, J. C., Martins, D. C., Nishioka, S., Pedrosa, A., de Siqueira, S. F., & Costa, R. (2008) · Arquivos Brasileiros de Cardiologia · doi:10.1590/s0066-782x2008000300004 · Cited by 7
Margos, P., Schomburg, R., Kynast, J., Khattab, A. A., & Richardt, G. (2009) · PubMed Central · Cited by 7
Predictors of successful defibrillation threshold test during CRT-D implantation.
Przybylski, A., Oręziak, A., Lewandowski, Z., Hasiec, A., Orczykowski, M., & Walczak, F. (2010) · PubMed · Cited by 7
Cheng, Z., Turakhia, M. P., Lo, R., Gupta, A., Zei, P. C., Hsia, H. H., Al‐Ahmad, A., & Wang, P. J. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9648-z · Cited by 6
The relationship between defibrillation threshold and total mortality
Rubenstein, J., Kim, M. H., Morady, F., & Strickberger, S. A. (2013) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-013-9831-5 · Cited by 6
Atrial Fibrillation and Ventricular Tachyarrhythmias: Advancements for Better Outcomes
Gheini, A., Pourya, A., & Pooria, A. (2020) · Cardiovascular & Haematological Disorders - Drug Targets · doi:10.2174/1871529x20666201001143907 · Cited by 6
Anti-arrhythmic drug therapy in implantable cardioverter-defibrillator recipients
AlTurki, A., Proietti, R., Russo, V., Dhanjal, T., Banerjee, P., & Essebag, V. (2019) · Pharmacological Research · doi:10.1016/j.phrs.2019.03.020 · Cited by 6
Hasan, A., & Yancy, C. W. (2007) · Congestive Heart Failure · doi:10.1111/j.1527-5299.2007.07329.x · Cited by 6
Chevalier, P., Timour, Q., Morel, É., & Bui‐Xuan, B. (2012) · Journal of Cardiovascular Pharmacology · doi:10.1097/fjc.0b013e31824d89fe · Cited by 5
Atrial Fibrillation in Patients with Implantable Defibrillators
Sakhuja, R., Shah, A. J., Keebler, M., & Thakur, R. K. (2008) · Cardiology Clinics · doi:10.1016/j.ccl.2008.09.014 · Cited by 5
Malhotra, R., Patel, S. A., Ramchand, T., & Nimri, O. A. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.07.002 · Cited by 5
Doldi, F., Willy, K., Wolfes, J., Ellermann, C., Taeger, S., Wegner, F. K., Güner, F., Korthals, D., Rath, B., Frommeyer, G., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14092859 · Cited by 4
Sequeira, O. R., Aquino, N. J., Gómez, N., García, L. B., Cáceres, C., Lovera, O. A., & Centurión, O. A. (2016) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1502 · Cited by 4
HBI-3000 Prevents Secondary Sudden Cardiac Death
Lee, J. Y., & Lucchesi, B. R. (2013) · Journal of Cardiovascular Pharmacology and Therapeutics · doi:10.1177/1074248413485433 · Cited by 4
Current Approaches to Antiarrhythmic Therapy in Heart Failure
Rose‐Jones, L. J., Bode, W. D., & Gehi, A. K. (2014) · Heart Failure Clinics · doi:10.1016/j.hfc.2014.07.010 · Cited by 6
Successful Catheter Ablation of the “R on T” Ventricular Fibrillation
Lasocka, Z., Dąbrowska-Kugacka, A., Lewicka, E., Liżewska-Springer, A., & Królak, T. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18189587 · Cited by 4
Arritmias y electrofisiología cardiaca
Garcı́a-Alberola, A., & Merino, J. L. (2007) · Revista Española de Cardiología · doi:10.1157/13099711 · Cited by 4
Sgarito, G. A., Campo, F., Sciacca, S., Pilato, M., Cipriani, M., & Conti, S. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14186604 · Cited by 3
Metadata
- Authors
- Hohnloser, S. H., Dorian, P., Roberts, R., Gent, M., Israel, C. W., Fain, E., Champagne, J., & Connolly, S. J.
- Affiliations
- Goethe University Frankfurt (DE)
- ORCID
- Venue
- Circulation
- Published
- 2006-07-11
- Volume
- 114
- Issue
- 2
- Pages
- 104-109
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2026225505
- Cited by
- 179
- References
- 31
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 4 · 2023: 5 · 2022: 3 · 2021: 7 · 2020: 4 · 2019: 7 · 2018: 9 · 2017: 11 · 2016: 6 · 2015: 10 · 2014: 6 · 2013: 10 · 2012: 19
- FWCI
- 9.72
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Funders
- McMaster University
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Keywords
- amiodarone, sotalol, implantable cardioverter-defibrillator, antiarrhythmic drugs, beta-blockers, defibrillation energy requirements, ICD shocks
- MeSH terms
- Carvedilol, Adrenergic beta-Antagonists, Aged, Amiodarone, Anti-Arrhythmia Agents, Atrial Fibrillation, Carbazoles, Combined Modality Therapy, Female, Heart Arrest, Humans, Male, Metoprolol, Middle Aged, Myocardial Infarction, Propanolamines, Sotalol, Ventricular Fibrillation, Ventricular Function, Left, Defibrillators, Implantable, Bisoprolol
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review