Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 184

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Three-Dimensional Mapping of Optimal Left Ventricular Pacing Site for Cardiac Resynchronization

Open access
Helm, Robert H., Byrne, Melissa, Helm, Patrick A., Daya, Samantapudi K., Osman, Nael F., Tunin, Richard, Halperin, Henry R., Berger, Ronald D., Kass, David A., Lardo, Albert C. · 2007 · Circulation

Abstract

Background— The efficacy of cardiac resynchronization therapy (CRT) depends on placement of the left ventricular lead within the late-activated territory. The geographic extent and 3-dimensional distribution of left ventricular (LV) locations yielding optimal CRT remain unknown. Methods and Results— Normal or tachypacing-induced failing canine hearts made dyssynchronous by right ventricular free wall pacing or chronic left bundle-branch ablation were acutely instrumented with a nonconstraining epicardial elastic sock containing 128 electrodes interfaced with a computer-controlled stimulation/recording system. Biventricular CRT was performed using a fixed right ventricular site and randomly selected LV sites covering the entire free wall. For each LV site, global cardiac function (conductance catheter) and mechanical synchrony (magnetic resonance imaging tagging) were determined to yield 3-dimensional maps reflecting CRT impact. Optimal CRT was achieved from LV lateral wall sites, slightly more anterior than posterior and more apical than basal. LV sites yielding ≥70% of the maximal dP/dtmax increase covered ≈43% of the LV free wall. This distribution and size were similar in both normal and failing hearts. The region was similar for various systolic and diastolic parameters and correlated with 3-dimensional maps based on mechanical synchrony from magnetic resonance imaging strain analysis. Conclusions— In hearts with delayed lateral contraction, optimized CRT is achieved over a fairly broad area of LV lateral wall in both nonfailing and failing hearts, with modest anterior or posterior deviation still capable of providing effective CRT. Sites selected to achieve the most mechanical synchrony are generally similar to those that most improve global function, confirming a key assumption underlying the use of wall motion analysis to optimize CRT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.643718

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 184

Metadata

Authors
Helm, R. H., Byrne, M., Helm, P. A., Daya, S. K., Osman, N. F., Tunin, R., Halperin, H. R., Berger, R. D., Kass, D. A., & Lardo, A. C.
Venue
Circulation
Published
2007-02-27
Volume
115
Issue
8
Pages
953-961
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1980210973
Cited by
184
References
2
FWCI
12.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-Dimensional Mapping of Optimal Left Ventricular Pacing Site for Cardiac Resynchronization. https://app.cochat.ai/papers/10.1161/circulationaha.106.643718
The paper
Helm, R. H., Byrne, M., Helm, P. A., Daya, S. K., Osman, N. F., Tunin, R., Halperin, H. R., Berger, R. D., Kass, D. A., & Lardo, A. C. (2007). Three-Dimensional Mapping of Optimal Left Ventricular Pacing Site for Cardiac Resynchronization. Circulation. https://doi.org/10.1161/circulationaha.106.643718

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.