The DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Role of Tissue Doppler and Strain Echocardiography in Current Clinical Practice
Open accessAbstract
The motion of a muscle, is performed only by the Carnous fibers, and each Carnous fiber has a power of contracting itself. . . .The force of the whole Muscle is but an aggregate of the contractions of each particular fiber.-William Croone in De ratione motus musculorum (On the Reason of the Movement of the Muscles), 1664 V isual or semiautomated tracking of the endocardial border provide estimates of cardiac volume, which are used to derive ejection fraction, a quantitative indicator of ventricular function.However, the heart is a complex mechanical organ that undergoes cyclic changes in multiple dimensions that ultimately effect a change in chamber volume that results in ejection of blood.Regardless of imaging technique, ejection fraction is unable to provide information on the underlying myocardial mechanical activity.Also, ejection fraction reflects the sum contribution of several regions and does not provide information on regional function.Regional function assessed visually is subjective and prone to error. 1 Quantification of regional myocardial activity (deformation) was feasible only in experimental studies by use of markers attached directly to the myocardium, a technique not practicable in the clinical realm. 2 Myocardial tagging with cardiac magnetic resonance (CMR) introduced the opportunity to noninvasively track regional myocardial mechanics.3,4 Modifications to the filter settings on pulsed Doppler to image low-velocity, high-intensity myocardial signal rather than the high-velocity, low-intensity signal from blood flow allows similar assessment by ultrasound.This technique is commonly referred to as tissue Doppler imaging (TDI) or Doppler myocardial imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Nagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.
Zerhouni, E. A., Parish, D. M., Rogers, W. J., Yang, A., & Shapiro, E. P. (1988) · Radiology · doi:10.1148/radiology.169.1.3420283 · Cited by 1,430
Noninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
Leitman, M., Lysyansky, P., Sidenko, S., Shir, V., Peleg, E., Binenbaum, M., Kaluski, E., Krakover, R., & Vered, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.06.019 · Cited by 1,187
MR imaging of motion with spatial modulation of magnetization.
Axel, L., & Dougherty, L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717762 · Cited by 1,150
Yu, C.-M., Chau, E., Sanderson, J. E., Fan, K., Tang, M.-O., Fung, W.-H., Lin, H., Kong, S.-L., Lam, Y.-M., Hill, M. R. S., et al. (2002) · Circulation · doi:10.1161/hc0402.102623 · Cited by 1,110
Cited by
Marwick, T. H., Gillebert, T. C., Aurigemma, G., Chirinos, J., Derumeaux, G., Galderisi, M., Gottdiener, J., Haluska, B., Ofili, E., Segers, P., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2015.05.002 · Cited by 583
Metadata
- Authors
- Abraham, T. P., Dimaano, V. L., & Liang, H.-Y.
- Venue
- Circulation
- Published
- 2007-11-27
- Volume
- 116
- Issue
- 22
- Pages
- 2597-2609
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2135833907
- Cited by
- 358
- References
- 77
- FWCI
- 13.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Role of Tissue Doppler and Strain Echocardiography in Current Clinical Practice. https://app.cochat.ai/papers/10.1161/circulationaha.106.647172
- The paper
- Abraham, T. P., Dimaano, V. L., & Liang, H.-Y. (2007). Role of Tissue Doppler and Strain Echocardiography in Current Clinical Practice. Circulation. https://doi.org/10.1161/circulationaha.106.647172
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.