Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 190

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Left Ventricular Resynchronization Is Mandatory for Response to Cardiac Resynchronization Therapy: Analysis in Patients With Echocardiographic Evidence of Left Ventricular Dyssynchrony at Baseline

Bleeker, Gabe B., Mollema, Sjoerd A., Holman, Eduard R., Van De Veire, Nico, Ypenburg, Claudia, Boersma, Eric, van der Wall, Ernst E., Schalij, Martin J., Bax, Jeroen J. · 2007 · Circulation

Abstract

Background— Recent studies have demonstrated that a positive response to cardiac resynchronization therapy (CRT) is related to the presence of preimplantation left ventricular (LV) dyssynchrony. The time course and the extent of LV resynchronization after CRT implantation and their relationship to response are currently unknown. Methods and Results— One hundred consecutive patients scheduled for implantation of a CRT device were prospectively included if they met the following criteria: New York Heart Association class III to IV, LV ejection fraction ≤35%, QRS duration >120 ms, and LV dyssynchrony (≥65 ms) on color-coded tissue Doppler imaging. Immediately after CRT implantation, LV dyssynchrony was reduced from 114±36 to 40±33 ms ( P <0.001), which persisted at the 6-month follow-up (35±31 ms; P <0.001 versus baseline; P =0.14 versus immediately after implantation). At the 6-month follow-up, 85% of patients were classified as responders to CRT (defined as >10% reduction in LV end-systolic volume). Immediately after implantation, the responders to CRT demonstrated a significant reduction in LV dyssynchrony from 115±37 to 32±23 ms ( P <0.001). The nonresponders, however, did not show a significant reduction in LV dyssynchrony (106±29 versus 79±44 ms; P =0.08). If the extent of acute LV resynchronization was <20%, response to CRT at the 6-month follow-up was never observed. Conversely, 93% of patients with LV resynchronization ≥20% responded to CRT. Conclusions— LV resynchronization after CRT is an acute phenomenon and predicts response to CRT at 6-month follow-up in patients with echocardiographic evidence of LV dyssynchrony at baseline.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.106.677005

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 190

Metadata

Authors
Bleeker, G. B., Mollema, S. A., Holman, E. R., Van De Veire, N., Ypenburg, C., Boersma, E., van der Wall, E. E., Schalij, M. J., & Bax, J. J.
Venue
Circulation
Published
2007-09-25
Volume
116
Issue
13
Pages
1440-1448
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2164030561
Cited by
190
References
7
FWCI
14.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left Ventricular Resynchronization Is Mandatory for Response to Cardiac Resynchronization Therapy: Analysis in Patients With Echocardiographic Evidence of Left Ventricular Dyssynchrony at Baseline. https://app.cochat.ai/papers/10.1161/circulationaha.106.677005
The paper
Bleeker, G. B., Mollema, S. A., Holman, E. R., Van De Veire, N., Ypenburg, C., Boersma, E., van der Wall, E. E., Schalij, M. J., & Bax, J. J. (2007). Left Ventricular Resynchronization Is Mandatory for Response to Cardiac Resynchronization Therapy: Analysis in Patients With Echocardiographic Evidence of Left Ventricular Dyssynchrony at Baseline. Circulation. https://doi.org/10.1161/circulationaha.106.677005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.