Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 557

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Implantable Cardioverter-Defibrillators in Tetralogy of Fallot

Khairy, Paul, Harris, Louise, Landzberg, Michael J., Viswanathan, Sangeetha, Barlow, Amanda, Gatzoulis, Michael A., Fernandes, Susan M., Beauchesne, Luc, Therrien, Judith, Chetaille, Philippe, Gordon, Elaine, Vonder Muhll, Isabelle, Cecchin, Frank·2008·Circulation

Abstract

Background— Tetralogy of Fallot is the most common form of congenital heart disease in implantable cardioverter-defibrillator (ICD) recipients, yet little is known about the value of ICDs in this patient population. Methods and Results— We conducted a multicenter cohort study in high-risk patients with Tetralogy of Fallot to determine actuarial rates of ICD discharges, identify risk factors, and characterize ICD-related complications. A total of 121 patients (median age 33.3 years; 59.5% male) were enrolled from 11 sites and followed up for a median of 3.7 years. ICDs were implanted for primary prevention in 68 patients (56.2%) and for secondary prevention in 53 (43.8%), defined by clinical sustained ventricular tachyarrhythmia or resuscitated sudden death. Overall, 37 patients (30.6%) received at least 1 appropriate and effective ICD discharge, with a median ventricular tachyarrhythmia rate of 213 bpm. Annual actuarial rates of appropriate ICD shocks were 7.7% and 9.8% in primary and secondary prevention, respectively ( P =0.11). A higher left ventricular end-diastolic pressure (hazard ratio 1.3 per mm Hg, P =0.004) and nonsustained ventricular tachycardia (hazard ratio 3.7, P =0.023) independently predicted appropriate ICD shocks in primary prevention. Inappropriate shocks occurred in 5.8% of patients yearly. Additionally, 36 patients (29.8%) experienced complications, of which 6 (5.0%) were acute, 25 (20.7%) were late lead-related, and 7 (5.8%) were late generator-related complications. Nine patients died during follow-up, which corresponds to an actuarial annual mortality rate of 2.2%, which did not differ between the primary and secondary prevention groups. Conclusions— Patients with tetralogy of Fallot and ICDs for primary and secondary prevention experience high rates of appropriate and effective shocks; however, inappropriate shocks and late lead-related complications are common.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.726372

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 557

Metadata

Authors
Khairy, P., Harris, L., Landzberg, M. J., Viswanathan, S., Barlow, A., Gatzoulis, M. A., Fernandes, S. M., Beauchesne, L., Therrien, J., Chetaille, P., Gordon, E., Vonder Muhll, I., & Cecchin, F.
Venue
Circulation
Published
2008-01-22
Volume
117
Issue
3
Pages
363-370
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2107640203
Cited by
557
References
4
FWCI
21.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Implantable Cardioverter-Defibrillators in Tetralogy of Fallot. https://app.cochat.ai/papers/10.1161/circulationaha.107.726372
The paper
Khairy, P., Harris, L., Landzberg, M. J., Viswanathan, S., Barlow, A., Gatzoulis, M. A., Fernandes, S. M., Beauchesne, L., Therrien, J., Chetaille, P., Gordon, E., Vonder Muhll, I., & Cecchin, F. (2008). Implantable Cardioverter-Defibrillators in Tetralogy of Fallot. Circulation. https://doi.org/10.1161/circulationaha.107.726372

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.