CoChat

Funny Current Downregulation and Sinus Node Dysfunction Associated With Atrial Tachyarrhythmia: A Molecular Basis for Tachycardia-Bradycardia Syndrome

Yeh, Yung-Hsin, Burstein, Brett, Qi, Xiao Yan, Sakabe, Masao, Chartier, Denis, Comtois, Philippe, Wang, Zhiguo, Kuo, Chi-Tai, Nattel, Stanley · 2009 · Circulation
Cited by 138

The DOI matches its Crossref record.

Abstract

Background— Sinoatrial node (SAN) dysfunction is frequently associated with atrial tachyarrhythmias (ATs). Abnormalities in SAN pacemaker function after termination of ATs can cause syncope and require pacemaker implantation, but underlying mechanisms remain poorly understood. This study examined the hypothesis that ATs impair SAN function by altering ion channel expression. Methods and Results— SAN tissues were obtained from 28 control dogs and 31 dogs with 7-day atrial tachypacing (400 bpm). Ionic currents were measured from single SAN cells with whole-cell patch-clamp techniques. Atrial tachypacing increased SAN recovery time in vivo by ≈70% ( P <0.01), a change which reflects impaired SAN function. In dogs that underwent atrial tachypacing, SAN mRNA expression (real-time reverse-transcription polymerase chain reaction) was reduced for hyperpolarization-activated cyclic nucleotide-gated subunits (HCN2 and HCN4) by >50% ( P <0.01) and for the β-subunit minK by ≈42% ( P <0.05). SAN transcript expression for the rapid delayed-rectifier ( I Kr ) α-subunit ERG, the slow delayed-rectifier ( I Ks ) α-subunit KvLQT1, the β-subunit MiRP1, the L-type ( I CaL ) and T-type ( I CaT ) Ca 2+ -current subunits Cav1.2 and Cav3.1, and the gap-junction subunit connexin 43 (were unaffected by atrial tachypacing. Atrial tachypacing reduced densities of the HCN-related funny current ( I f ) and I Ks by ≈48% ( P <0.001) and ≈34% ( P <0.01), respectively, with no change in voltage dependence or kinetics. I Kr , I CaL , and I CaT were unaffected. SAN cells lacked Ba 2+ -sensitive inward-rectifier currents, irrespective of AT. SAN action potential simulations that incorporated AT-induced alterations in I f accounted for slowing of periodicity, with no additional contribution from changes in I Ks . Conclusions— AT downregulates SAN HCN2/4 and minK subunit expression, along with the corresponding currents I f and I Ks . Tachycardia-induced remodeling of SAN ion channel expression, particularly for the “pacemaker” subunit I f , may contribute to the clinically significant association between SAN dysfunction and supraventricular tachyarrhythmias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.789677

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 138

Metadata

Authors
Yeh, Y.-H., Burstein, B., Qi, X. Y., Sakabe, M., Chartier, D., Comtois, P., Wang, Z., Kuo, C.-T., & Nattel, S.
Venue
Circulation
Published
2009-03-31
Volume
119
Issue
12
Pages
1576-1585
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2151309874
Cited by
138
References
0
FWCI
6.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Funny Current Downregulation and Sinus Node Dysfunction Associated With Atrial Tachyarrhythmia: A Molecular Basis for Tachycardia-Bradycardia Syndrome. https://app.cochat.ai/papers/10.1161/circulationaha.108.789677
The paper
Yeh, Y.-H., Burstein, B., Qi, X. Y., Sakabe, M., Chartier, D., Comtois, P., Wang, Z., Kuo, C.-T., & Nattel, S. (2009). Funny Current Downregulation and Sinus Node Dysfunction Associated With Atrial Tachyarrhythmia: A Molecular Basis for Tachycardia-Bradycardia Syndrome. Circulation. https://doi.org/10.1161/circulationaha.108.789677

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.