Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 214

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of the Novel Myocardial Perfusion Positron-Emission Tomography Tracer 18 F-BMS-747158-02: Comparison to 13 N-Ammonia and Validation With Microspheres in a Pig Model

Nekolla, S.G., Reder, S., Saraste, A., Higuchi, T., Dzewas, G., Preissel, A., Huisman, M., Poethko, T., Schuster, T., Yu, M., Robinson, S., Casebier, D., Henke, J., Wester, H.J., Schwaiger, M. · 2009 · Circulation

Abstract

Background— Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18 F-BMS-747158-02 ( 18 F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13 N-ammonia ( 13 NH 3 ) and with radioactive microspheres in a pig model. Methods and Results— Fourteen pigs injected with 500 MBq of 13 NH 3 or 100 to 200 MBq of 18 F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18 F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18 F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13 NH 3 , 18 F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18 F-BMS PET showed good correlation ( r =0.88, slope=0.84) and agreement (mean difference −0.10 [25th percentile −0.3, 75th percentile 0.1 mL · min −1 · g −1 ]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL · min −1 · g −1 . The extent of defects induced by left anterior descending coronary artery constriction measured by 18 F-BMS and microspheres also correlated closely ( r =0.63, slope=1.1). Conclusions— 18 F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18 F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.797761

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 214

Metadata

Authors
Nekolla, S. G., Reder, S., Saraste, A., Higuchi, T., Dzewas, G., Preissel, A., Huisman, M., Poethko, T., Schuster, T., Yu, M., Robinson, S., Casebier, D., Henke, J., Wester, H. J., & Schwaiger, M.
Venue
Circulation
Published
2009-05-05
Volume
119
Issue
17
Pages
2333-2342
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2067296336
Cited by
214
References
1
FWCI
15.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.