Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 511

The DOI matches its Crossref record.

Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis

Open access
Unverdorben, Martin, Vallbracht, Christian, Cremers, Bodo, Heuer, Hubertus, Hengstenberg, Christian, Maikowski, Christian, Werner, Gerald S., Antoni, Diethmar, Kleber, Franz X., Bocksch, Wolfgang, Leschke, Matthias, Ackermann, Hanns, Boxberger, Michael, Speck, Ulrich, Degenhardt, Ralf, Scheller, Bruno·2009·Circulation

Abstract

Background— Treatment of in-stent restenosis with paclitaxel-coated balloon catheter as compared with plain balloon angioplasty has shown surprisingly low late lumen loss at 6 months and fewer major adverse cardiac events up to 2 years. We compared the efficacy and safety of a paclitaxel-coated balloon with a paclitaxel-eluting stent as the current standard of care. Methods and Results— One hundred thirty-one patients with coronary in-stent restenosis were randomly assigned to treatment by a paclitaxel-coated balloon (3 μg/mm 2 ) or a paclitaxel-eluting stent. The main inclusion criteria encompassed diameter stenosis of ≥70% and ≤22 mm in length, with a vessel diameter of 2.5 to 3.5 mm. The primary end point was angiographic in-segment late lumen loss. Quantitative coronary angiography revealed no differences in baseline parameters. At 6 months follow-up, in-segment late lumen loss was 0.38±0.61 mm in the drug-eluting stent group versus 0.17±0.42 mm ( P =0.03) in the drug-coated balloon group, resulting in a binary restenosis rate of 12 of 59 (20%) versus 4 of 57 (7%; P =0.06). At 12 months, the rate of major adverse cardiac events were 22% and 9%, respectively ( P =0.08). This difference was primarily due to the need for target lesion revascularization in 4 patients (6%) in the coated-balloon group, compared with 10 patients (15%) in the stent group ( P =0.15). Conclusions— Treatment of coronary in-stent restenosis with the paclitaxel-coated balloon was at least as efficacious and as well tolerated as the paclitaxel-eluting stent. For the treatment of in-stent restenosis, inhibition of re-restenosis does not require a second stent implantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.839282

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 511

Metadata

Authors
Unverdorben, M., Vallbracht, C., Cremers, B., Heuer, H., Hengstenberg, C., Maikowski, C., Werner, G. S., Antoni, D., Kleber, F. X., Bocksch, W., Leschke, M., Ackermann, H., Boxberger, M., Speck, U., Degenhardt, R., & Scheller, B.
Venue
Circulation
Published
2009-06-16
Volume
119
Issue
23
Pages
2986-2994
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2109769695
Cited by
511
References
0
FWCI
46.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis. https://app.cochat.ai/papers/10.1161/circulationaha.108.839282
The paper
Unverdorben, M., Vallbracht, C., Cremers, B., Heuer, H., Hengstenberg, C., Maikowski, C., Werner, G. S., Antoni, D., Kleber, F. X., Bocksch, W., Leschke, M., Ackermann, H., Boxberger, M., Speck, U., Degenhardt, R., & Scheller, B. (2009). Paclitaxel-Coated Balloon Catheter Versus Paclitaxel-Coated Stent for the Treatment of Coronary In-Stent Restenosis. Circulation. https://doi.org/10.1161/circulationaha.108.839282

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.