Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record.

Location of Cardiac Arrest in a City Center: Strategic Placement of Automated External Defibrillators in Public Locations

Folke, Fredrik, Lippert, Freddy Knudsen, Nielsen, Søren Loumann, Gislason, Gunnar Hilmar, Hansen, Morten Lock, Schramm, Tina Ken, Sørensen, Rikke, Fosbøl, Emil Loldrup, Andersen, Søren Skøtt, Rasmussen, Søren, Køber, Lars, Torp-Pedersen, Christian · 2009 · Circulation

Abstract

Background— Public-access defibrillation with automated external defibrillators (AEDs) is being implemented in many countries worldwide with considerable financial implications. The potential benefit and economic consequences of focused or unfocused AED deployment are unknown. Methods and Results— All cardiac arrests in public in Copenhagen, Denmark, from 1994 through 2005 were geographically located, as were 104 public AEDs placed by local initiatives. In accordance with European Resuscitation Council and American Heart Association (AHA) guidelines, areas with a high incidence of cardiac arrests were defined as those with 1 cardiac arrest every 2 or 5 years, respectively. There were 1274 cardiac arrests in public locations. According to the European Resuscitation Council or AHA guidelines, AEDs needed to be deployed in 1.2% and 10.6% of the city area, providing coverage for 19.5% (n=249) and 66.8% (n=851) of all cardiac arrests, respectively. The excessive cost of such AED deployments was estimated to be $33 100 or $41 000 per additional quality-adjusted life year, whereas unguided AED placement covering the entire city had an estimated cost of $108 700 per quality-adjusted life year. Areas with major train stations (1.8 arrests every 5 years per area), large public squares, and pedestrianized areas (0.6 arrests every 5 years per area) were main predictors of frequent cardiac arrests. Conclusion— To achieve wide AED coverage, AEDs need to be more widely distributed than recommended by the European Resuscitation Council guidelines but consistent with the American Heart Association guidelines. Strategic placement of AEDs is pivotal for public-access defibrillation, whereas with unguided initiatives, AEDs are likely to be placed inappropriately.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.108.843755

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 216

Metadata

Authors
Folke, F., Lippert, F. K., Nielsen, S. L., Gislason, G. H., Hansen, M. L., Schramm, T. K., Sørensen, R., Fosbøl, E. L., Andersen, S. S., Rasmussen, S., Køber, L., & Torp-Pedersen, C.
Venue
Circulation
Published
2009-08-11
Volume
120
Issue
6
Pages
510-517
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2140492377
Cited by
216
References
0
FWCI
13.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Location of Cardiac Arrest in a City Center: Strategic Placement of Automated External Defibrillators in Public Locations. https://app.cochat.ai/papers/10.1161/circulationaha.108.843755
The paper
Folke, F., Lippert, F. K., Nielsen, S. L., Gislason, G. H., Hansen, M. L., Schramm, T. K., Sørensen, R., Fosbøl, E. L., Andersen, S. S., Rasmussen, S., Køber, L., & Torp-Pedersen, C. (2009). Location of Cardiac Arrest in a City Center: Strategic Placement of Automated External Defibrillators in Public Locations. Circulation. https://doi.org/10.1161/circulationaha.108.843755

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.