Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 367

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Percutaneous Mitral Annuloplasty for Functional Mitral Regurgitation: Results of the CARILLON Mitral Annuloplasty Device European Union Study

Open access
Schofer, Joachim, Siminiak, Tomasz, Haude, Michael, Herrman, Jean P., Vainer, Jindra, Wu, Justina C., Levy, Wayne C., Mauri, Laura, Feldman, Ted, Kwong, Raymond Y., Kaye, David M., Duffy, Stephen J., Tübler, Thilo, Degen, Hubertus, Brandt, Mathias C., Van Bibber, Rich, Goldberg, Steve, Reuter, David G., Hoppe, Uta C.·2009·Circulation

Abstract

Background— Functional mitral regurgitation (FMR), a well-recognized component of left ventricular remodeling, is associated with increased morbidity and mortality in heart failure patients. Percutaneous mitral annuloplasty has the potential to serve as a therapeutic adjunct to standard medical care. Methods and Results— Patients with dilated cardiomyopathy, moderate to severe FMR, an ejection fraction <40%, and a 6-minute walk distance between 150 and 450 m were enrolled in the CARILLON Mitral Annuloplasty Device European Union Study (AMADEUS). Percutaneous mitral annuloplasty was achieved through the coronary sinus with the CARILLON Mitral Contour System. Echocardiographic FMR grade, exercise tolerance, New York Heart Association class, and quality of life were assessed at baseline and 1 and 6 months. Of the 48 patients enrolled in the trial, 30 received the CARILLON device. Eighteen patients did not receive a device because of access issues, insufficient acute FMR reduction, or coronary artery compromise. The major adverse event rate was 13% at 30 days. At 6 months, the degree of FMR reduction among 5 different quantitative echocardiographic measures ranged from 22% to 32%. Six-minute walk distance improved from 307±87 m at baseline to 403±137 m at 6 months ( P <0.001). Quality of life, measured by the Kansas City Cardiomyopathy Questionnaire, improved from 47±16 points at baseline to 69±15 points at 6 months ( P <0.001). Conclusions— Percutaneous reduction in FMR with a novel coronary sinus–based mitral annuloplasty device is feasible in patients with heart failure, is associated with a low rate of major adverse events, and is associated with improvement in quality of life and exercise tolerance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.849885

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 367

Metadata

Authors
Schofer, J., Siminiak, T., Haude, M., Herrman, J. P., Vainer, J., Wu, J. C., Levy, W. C., Mauri, L., Feldman, T., Kwong, R. Y., Kaye, D. M., Duffy, S. J., Tübler, T., Degen, H., Brandt, M. C., Van Bibber, R., Goldberg, S., Reuter, D. G., & Hoppe, U. C.
Venue
Circulation
Published
2009-07-28
Volume
120
Issue
4
Pages
326-333
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1978806183
Cited by
367
References
2
FWCI
18.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Percutaneous Mitral Annuloplasty for Functional Mitral Regurgitation: Results of the CARILLON Mitral Annuloplasty Device European Union Study. https://app.cochat.ai/papers/10.1161/circulationaha.109.849885
The paper
Schofer, J., Siminiak, T., Haude, M., Herrman, J. P., Vainer, J., Wu, J. C., Levy, W. C., Mauri, L., Feldman, T., Kwong, R. Y., Kaye, D. M., Duffy, S. J., Tübler, T., Degen, H., Brandt, M. C., Van Bibber, R., Goldberg, S., Reuter, D. G., & Hoppe, U. C. (2009). Percutaneous Mitral Annuloplasty for Functional Mitral Regurgitation: Results of the CARILLON Mitral Annuloplasty Device European Union Study. Circulation. https://doi.org/10.1161/circulationaha.109.849885

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.