Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record.

Mechanisms by Which Adenosine Restores Conduction in Dormant Canine Pulmonary Veins

Datino, Tomás, Macle, Laurent, Qi, Xiao-Yan, Maguy, Ange, Comtois, Philippe, Chartier, Denis, Guerra, Peter G., Arenal, Angel, Fernández-Avilés, Francisco, Nattel, Stanley·2010·Circulation

Abstract

Background— Adenosine acutely reconnects pulmonary veins (PVs) after radiofrequency application, revealing “dormant conduction” and identifying PVs at risk of reconnection, but the underlying mechanisms are unknown. Methods and Results— Canine PV and left-atrial (LA) action potentials were recorded with standard microelectrodes and ionic currents with whole-cell patch clamp before and after adenosine perfusion. PVs were isolated with radiofrequency current application in coronary-perfused LA-PV preparations. Adenosine abbreviated action potential duration similarly in PV and LA but significantly hyperpolarized resting potential (by 3.9±0.5%; P <0.05) and increased dV/dt max (by 34±10%) only in PV. Increased dV/dt max was not due to direct effects on I Na , which was reduced similarly by adenosine in LA and PV but correlated with resting-potential hyperpolarization ( r =0.80). Adenosine induced larger inward rectifier K + current (I KAdo ) in PV (eg, −2.28±0.04 pA/pF; −100 mV) versus LA (−1.28±0.16 pA/pF). Radiofrequency ablation isolated PVs by depolarizing resting potential to voltages positive to −60 mV. Adenosine restored conduction in 5 dormant PVs, which had significantly more negative resting potentials (−57±6 mV) versus nondormant (−46±5 mV, n=6; P <0.001) before adenosine. Adenosine hyperpolarized both, but more negative resting-potential values after adenosine in dormant PVs (−66±6 mV versus −56±6 mV in nondormant; P <0.001) were sufficient to restore excitability. Adenosine effects on resting potential and conduction reversed on washout. Spontaneous recovery of conduction occurring in dormant PVs after 30 to 60 minutes was predicted by the adenosine response. Conclusions— Adenosine selectively hyperpolarizes canine PVs by increasing I KAdo . PVs with dormant conduction show less radiofrequency-induced depolarization than nondormant veins, allowing adenosine-induced hyperpolarization to restore excitability by removing voltage-dependent I Na inactivation and explaining the restoration of conduction in dormant PVs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.893107

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Datino, T., Macle, L., Qi, X.-Y., Maguy, A., Comtois, P., Chartier, D., Guerra, P. G., Arenal, A., Fernández-Avilés, F., & Nattel, S.
Venue
Circulation
Published
2010-03-02
Volume
121
Issue
8
Pages
963-972
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2093694628
Cited by
196
References
0
FWCI
12.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanisms by Which Adenosine Restores Conduction in Dormant Canine Pulmonary Veins. https://app.cochat.ai/papers/10.1161/circulationaha.109.893107
The paper
Datino, T., Macle, L., Qi, X.-Y., Maguy, A., Comtois, P., Chartier, D., Guerra, P. G., Arenal, A., Fernández-Avilés, F., & Nattel, S. (2010). Mechanisms by Which Adenosine Restores Conduction in Dormant Canine Pulmonary Veins. Circulation. https://doi.org/10.1161/circulationaha.109.893107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.