Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 370

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve

Open access
Aicher, Diana, Kunihara, Takashi, Abou Issa, Omar, Brittner, Brigitte, Gräber, Stefan, Schäfers, Hans-Joachim · 2011 · Circulation

Abstract

Background—: Reconstruction of the regurgitant bicuspid aortic valve has been performed for >10 years, but there is limited information on long-term results. We analyzed our results to determine the predictors of suboptimal outcome. Methods and Results—: Between November 1995 and December 2008, 316 patients (age, 49±14 years; male, 268) underwent reconstruction of a regurgitant bicuspid aortic valve. Intraoperative assessment included extent of fusion, root dimensions, circumferential orientation of the 2 normal commissures (>160°, ≤160°), and effective height after repair. Cusp pathology was treated by central plication (n=277), triangular resection (n=138), or pericardial patch (n=94). Root dilatation was treated by subcommissural plication (n=100), root remodeling (n=122), or valve reimplantation (n=2). All patients were followed up echocardiographically (cumulative follow-up, 1253 years; mean, 4±3.1 years). Clinical and morphological parameters were analyzed for correlation with 10-year freedom from reoperation with the Cox proportional hazards model. Hospital mortality was 0.63%; survival was 92% at 10 years. Freedom from reoperation at 5 and 10 years was 88% and 81%; freedom from valve replacement, 95% and 84%. By univariable analysis, statistically significant predictors of reoperation were age (hazard ratio [HR]=0.97), aortoventricular diameter (HR=1.24), effective height (HR=0.76), commissural orientation (HR=0.95), use of a pericardial patch (HR=7.63), no root replacement (HR=3.80), subcommissural plication (HR=2.07), and preoperative aortic regurgitation grade 3 or greater. By multivariable analysis, statistically significant predictors for reoperation were age (HR=0.96), aortoventricular diameter (HR=1.30), effective height (HR=0.74), commissural orientation (HR=0.96), and use of a pericardial patch (HR=5.16). Conclusions—: Reconstruction of bicuspid aortic valve can be performed reproducibly with good early results. Recurrence and progression of regurgitation, however, may occur, depending primarily on anatomic features of the valve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.934679

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 370

Metadata

Authors
Aicher, D., Kunihara, T., Abou Issa, O., Brittner, B., Gräber, S., & Schäfers, H.-J.
Venue
Circulation
Published
2011-01-18
Volume
123
Issue
2
Pages
178-185
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2160400800
Cited by
370
References
14
FWCI
19.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve. https://app.cochat.ai/papers/10.1161/circulationaha.109.934679
The paper
Aicher, D., Kunihara, T., Abou Issa, O., Brittner, B., Gräber, S., & Schäfers, H.-J. (2011). Valve Configuration Determines Long-Term Results After Repair of the Bicuspid Aortic Valve. Circulation. https://doi.org/10.1161/circulationaha.109.934679

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.