Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 328

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT)

Goldenberg, Ilan, Moss, Arthur J., Hall, W. Jackson, Foster, Elyse, Goldberger, Jeffrey J., Santucci, Peter, Shinn, Timothy, Solomon, Scott, Steinberg, Jonathan S., Wilber, David, Barsheshet, Alon, McNitt, Scott, Zareba, Wojciech, Klein, Helmut·2011·Circulation

Abstract

Background—: We hypothesized that combined assessment of factors that are associated with favorable reverse remodeling after cardiac resynchronization-defibrillator therapy (CRT-D) can be used to predict clinical response to the device. Methods and Results—: The study population comprised 1761 patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). Best-subset regression analysis was performed to identify factors associated with echocardiographic response (defined as percent reduction in left ventricular end-diastolic volume 1 year after CRT-D implantation) and to create a response score. Cox proportional hazards regression analysis was used to evaluate the CRT-D versus defibrillator-only reduction in the risk of heart failure or death by the response score. Seven factors were identified as associated with echocardiographic response to CRT-D and made up the response score (female sex, nonischemic origin, left bundle-branch block, QRS ≥150 milliseconds, prior hospitalization for heart failure, left ventricular end-diastolic volume ≥125 mL/m 2 , and left atrial volume <40 mL/m 2 ). Multivariate analysis showed a 13% ( P <0.001) increase in the clinical benefit of CRT-D per 1-point increment in the response score (range, 0–14) and a significant direct correlation between risk reduction associated with CRT-D and response score quartiles: Patients in the first quartile did not derive a significant reduction in the risk of heart failure or death with CRT-D (hazard ratio=0.87; P =0.52); patients in the second and third quartiles derived 33% ( P =0.04) and 36% ( P =0.03) risk reductions, respectively; and patients in the upper quartile experienced a 69% ( P <0.001) risk reduction ( P for trend=0.005). Conclusion—: Combined assessment of factors associated with reverse remodeling can be used for improved selection of patients for cardiac resynchronization therapy. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00180271.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.014324

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 328

Metadata

Authors
Goldenberg, I., Moss, A. J., Hall, W. J., Foster, E., Goldberger, J. J., Santucci, P., Shinn, T., Solomon, S., Steinberg, J. S., Wilber, D., Barsheshet, A., McNitt, S., Zareba, W., & Klein, H.
Venue
Circulation
Published
2011-10-04
Volume
124
Issue
14
Pages
1527-1536
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2025139676
Cited by
328
References
34
FWCI
20.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). https://app.cochat.ai/papers/10.1161/circulationaha.110.014324
The paper
Goldenberg, I., Moss, A. J., Hall, W. J., Foster, E., Goldberger, J. J., Santucci, P., Shinn, T., Solomon, S., Steinberg, J. S., Wilber, D., Barsheshet, A., McNitt, S., Zareba, W., & Klein, H. (2011). Predictors of Response to Cardiac Resynchronization Therapy in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT). Circulation. https://doi.org/10.1161/circulationaha.110.014324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.