The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Long-Term Benefit of Primary Prevention With an Implantable Cardioverter-Defibrillator: An Extended 8-Year Follow-Up Study of the Multicenter Automatic Defibrillator Implantation Trial II
Abstract
Background—: The Multicenter Automatic Defibrillator Implantation Trial II (MADIT-II) showed a significant 31 reduction in the risk of death with primary implantable cardioverter-defibrillator (ICD) therapy during a median follow-up of 1.5 years. However, currently there are no data on the long-term efficacy of primary defibrillator therapy. Methods and Results—: MADIT-II enrolled 1232 patients with ischemic left ventricular dysfunction who were randomized to ICD and non-ICD medical therapy and were followed up through November 2001. For the present long-term study, we acquired posttrial mortality data through March 2009 for all study participants (median follow-up, 7.6 years). Multivariate Cox proportional hazards regression modeling was performed to calculate the hazard ratio for ICD versus non-ICD therapy during long-term follow-up. At 8 years of follow-up, the cumulative probability of all-cause mortality was 49 among patients treated with an ICD compared with 62 among non-ICD patients ( P <0.001). Multivariate analysis demonstrated that ICD therapy was associated with a significant long-term survival benefit (hazard ratio for 0- through 8-year mortality=0.66 [95 confidence interval, 0.56 to 0.78]; P <0.001). Treatment with an ICD was shown to be associated with a significant reduction in the risk of death during the early phase of the extended follow-up period (0 through 4 years: hazard ratio=0.61 [95 confidence interval, 0.50 to 0.76]; P <0.001) and with continued life-saving benefit during the late phase of follow-up (5 through 8 years: hazard ratio=0.74 [95 confidence interval, 0.57 to 0.96]; P =0.02). Conclusions—: Our findings demonstrate a sustained 8-year survival benefit with primary ICD therapy in the MADIT-II population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Self-citationA Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Cited by
WRITING COMMITTEE MEMBERS*, O’Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., et al. (2013) · Circulation · doi:10.1161/cir.0b013e3182742cf6 · Cited by 4,725
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
2013 ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction
O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Chung, M. K., de Lemos, J. A., Ettinger, S. M., Fang, J. C., Fesmire, F. M., Franklin, B. A., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.019 · Cited by 2,625
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
(2015) · Europace · doi:10.1093/europace/euv319 · Cited by 1,592
Metadata
- Authors
- Goldenberg, I., Gillespie, J., Moss, A. J., Hall, W. J., Klein, H., McNitt, S., Brown, M. W., Cygankiewicz, I., Zareba, W., & and the Executive Committee of the Multicenter Automatic Defibrillator Implantation Trial II
- Venue
- Circulation
- Published
- 2010-09-28
- Volume
- 122
- Issue
- 13
- Pages
- 1265-1271
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2165158924
- Cited by
- 230
- References
- 5
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.