Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Who Are the Long-QT Syndrome Patients Who Receive an Implantable Cardioverter-Defibrillator and What Happens to Them?: Data From the European Long-QT Syndrome Implantable Cardioverter-Defibrillator (LQTS ICD) Registry

Open access
Schwartz, Peter J., Spazzolini, Carla, Priori, Silvia G., Crotti, Lia, Vicentini, Alessandro, Landolina, Maurizio, Gasparini, Maurizio, Wilde, Arthur A.M., Knops, Reinoud E., Denjoy, Isabelle, Toivonen, Lauri, Mönnig, Gerold, Al-Fayyadh, Majid, Jordaens, Luc, Borggrefe, Martin, Holmgren, Christina, Brugada, Pedro, De Roy, Luc, Hohnloser, Stefan H., Brink, Paul A.·2010·Circulation

Abstract

Background—: A rapidly growing number of long-QT syndrome (LQTS) patients are being treated with an implantable cardioverter-defibrillator (ICD). ICDs may pose problems, especially in the young. We sought to determine the characteristics of the LQTS patients receiving an ICD, the indications, and the aftermath. Methods and Results—: The study population included 233 patients. Beginning in 2002, data were collected prospectively. Female patients (77%) and LQT3 patients (22% of genotype positive) were overrepresented; mean QTc was 516±65 milliseconds; mean age at implantation was 30±17 years; and genotype was known in 59% of patients. Unexpectedly, 9% of patients were asymptomatic before implantation. Asymptomatic patients, almost absent among LQT1 and LQT2 patients, represented 45% of LQT3 patients. Patients with cardiac symptoms made up 91% of all study participants, but only 44% had cardiac arrest before ICD implantation. In addition, 41% of patients received an ICD without having first been on LQTS therapy. During follow-up, 4.6±3.2 years, at least 1 appropriate shock was received by 28% of patients, and adverse events occurred in 25%. Appropriate ICD therapies were predicted by age <20 years at implantation, a QTc >500 milliseconds, prior cardiac arrest, and cardiac events despite therapy; within 7 years, appropriate shocks occurred in no patients with none of these factors and in 70% of those with all factors. Conclusions—: Reflecting previous concepts, ICDs were implanted in some LQTS patients whose high risk now appears questionable. Refined criteria for implantation, reassessment of pros and cons, ICD reprogramming, and consideration for other existing therapeutic options are necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.110.950147

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 307

Metadata

Authors
Schwartz, P. J., Spazzolini, C., Priori, S. G., Crotti, L., Vicentini, A., Landolina, M., Gasparini, M., Wilde, A. A. M., Knops, R. E., Denjoy, I., Toivonen, L., Mönnig, G., Al-Fayyadh, M., Jordaens, L., Borggrefe, M., Holmgren, C., Brugada, P., De Roy, L., Hohnloser, S. H., & Brink, P. A.
Venue
Circulation
Published
2010-09-28
Volume
122
Issue
13
Pages
1272-1282
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2154794710
Cited by
307
References
1
FWCI
17.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Who Are the Long-QT Syndrome Patients Who Receive an Implantable Cardioverter-Defibrillator and What Happens to Them?: Data From the European Long-QT Syndrome Implantable Cardioverter-Defibrillator (LQTS ICD) Registry. https://app.cochat.ai/papers/10.1161/circulationaha.110.950147
The paper
Schwartz, P. J., Spazzolini, C., Priori, S. G., Crotti, L., Vicentini, A., Landolina, M., Gasparini, M., Wilde, A. A. M., Knops, R. E., Denjoy, I., Toivonen, L., Mönnig, G., Al-Fayyadh, M., Jordaens, L., Borggrefe, M., Holmgren, C., Brugada, P., De Roy, L., Hohnloser, S. H., & Brink, P. A. (2010). Who Are the Long-QT Syndrome Patients Who Receive an Implantable Cardioverter-Defibrillator and What Happens to Them?: Data From the European Long-QT Syndrome Implantable Cardioverter-Defibrillator (LQTS ICD) Registry. Circulation. https://doi.org/10.1161/circulationaha.110.950147

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.