Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Comparison of Cardiovascular Magnetic Resonance and Single-Photon Emission Computed Tomography in Women With Suspected Coronary Artery Disease From the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) Trial

Open access
Greenwood, John P., Motwani, Manish, Maredia, Neil, Brown, Julia M., Everett, Colin C., Nixon, Jane, Bijsterveld, Petra, Dickinson, Catherine J., Ball, Stephen G., Plein, Sven · 2014 · Circulation

Abstract

Background—: Coronary artery disease is the leading cause of death in women, and underdiagnosis contributes to the high mortality. This study compared the sex-specific diagnostic performance of cardiovascular magnetic resonance (CMR) and single-photon emission computed tomography (SPECT). Methods and Results—: A total of 235 women and 393 men with suspected angina underwent CMR, SPECT, and x-ray angiography as part of the Clinical Evaluation of Magnetic Resonance Imaging in Coronary Heart Disease (CE-MARC) study. CMR comprised adenosine stress/rest perfusion, cine imaging, late gadolinium enhancement, and magnetic resonance coronary angiography. Gated adenosine stress/rest SPECT was performed with 99m Tc-tetrofosmin. For CMR, the sensitivity in women and men was similar (88.7% versus 85.6%; P =0.57), as was the specificity (83.5% versus 82.8%; P =0.86). For SPECT, the sensitivity was significantly worse in women than in men (50.9% versus 70.8%; P =0.007), but the specificities were similar (84.1% versus 81.3%; P =0.48). The sensitivity in both the female and male groups was significantly higher with CMR than SPECT ( P <0.0001 for both), but the specificity was similar ( P =0.77 and P =1.00, respectively). For perfusion-only components, CMR outperformed SPECT in women (area under the curve, 0.90 versus 0.67; P <0.0001) and in men (area under the curve, 0.89 versus 0.74; P <0.0001). Diagnostic accuracy was similar in both sexes with perfusion CMR ( P =1.00) but was significantly worse in women with SPECT ( P <0.0001). Conclusions—: In both sexes, CMR has greater sensitivity than SPECT. Unlike SPECT, there are no significant sex differences in the diagnostic performance of CMR. These findings, plus an absence of ionizing radiation exposure, mean that CMR should be more widely adopted in women with suspected coronary artery disease. Clinical Trial Registration—: URL: http://www.controlled-trials.com . Unique identifier: ISRCTN77246133.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.112.000071

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Greenwood, J. P., Motwani, M., Maredia, N., Brown, J. M., Everett, C. C., Nixon, J., Bijsterveld, P., Dickinson, C. J., Ball, S. G., & Plein, S.
Venue
Circulation
Published
2014-03-11
Volume
129
Issue
10
Pages
1129-1138
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2007891504
Cited by
176
References
4
FWCI
11.17
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.