Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study

Open access
Atallah, Joseph, Erickson, Christopher C., Cecchin, Frank, Dubin, Anne M., Law, Ian H., Cohen, Mitchell I., LaPage, Martin J., Cannon, Bryan C., Chun, Terrence U.H., Freedenberg, Vicki, Gierdalski, Marcin, Berul, Charles I. · 2013 · Circulation

Abstract

Background—: Implantable cardioverter-defibrillator (ICD) therapy in children and congenital heart disease patients is hampered by poor long-term lead survival. Lead extraction is technically difficult and carries substantial morbidity. We sought to determine the outcomes of ICD leads in pediatric and congenital heart disease patients. Methods and Results—: The Pediatric Lead Extractability and Survival Evaluation (PLEASE) is a 24-center international registry. Pediatric and congenital heart disease patients with ICD lead implantations from 2005 to 2010 were eligible. Study subjects comprised 878 ICD patients (44% congenital heart disease). Mean±SD age at implantation was 18.6±9.8 years. Of the 965 total leads, 54% were thin (≤7F), of which 57% were Fidelis, and 23% were coated with expanded polytetrafluoroethylene. There were 139 ICD lead failures (14%) in 132 patients (15%) at a mean lead age of 2.0±1.4 years, causing shocks in 53 patients (40%). Independent predictors of lead failure included younger implantation age and Fidelis leads. Actuarial analysis showed an incremental risk of lead failure with younger age at implantation: <8 years compared with >18 years ( P =0.015). The actuarial yearly failure rate was 2.3% for non-Fidelis and 9.1% for Fidelis leads. Extraction was performed on 143 leads (80% thin, 7% expanded polytetrafluoroethylene coated), with lead age as the only independent predictor for advanced extraction techniques. There were 6 major extraction complications (4%) but no procedural mortality. Conclusions—: This study demonstrates that ICD leads in children and congenital heart disease patients have an age-related suboptimal performance, further compounded by a high failure rate of Fidelis leads. Advanced extraction techniques were common and correlated with older lead age. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00335036.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.112.001120

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Atallah, J., Erickson, C. C., Cecchin, F., Dubin, A. M., Law, I. H., Cohen, M. I., LaPage, M. J., Cannon, B. C., Chun, T. U. H., Freedenberg, V., Gierdalski, M., & Berul, C. I.
Venue
Circulation
Published
2013-06-18
Volume
127
Issue
24
Pages
2393-2402
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2011722605
Cited by
183
References
0
FWCI
10.38
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study. https://app.cochat.ai/papers/10.1161/circulationaha.112.001120
The paper
Atallah, J., Erickson, C. C., Cecchin, F., Dubin, A. M., Law, I. H., Cohen, M. I., LaPage, M. J., Cannon, B. C., Chun, T. U. H., Freedenberg, V., Gierdalski, M., & Berul, C. I. (2013). Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study. Circulation. https://doi.org/10.1161/circulationaha.112.001120

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.