Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 583

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves: Results From the Global Valve-in-Valve Registry

Open access
Dvir, Danny, Webb, John, Brecker, Stephen, Bleiziffer, Sabine, Hildick-Smith, David, Colombo, Antonio, Descoutures, Fleur, Hengstenberg, Christian, Moat, Neil E., Bekeredjian, Raffi, Napodano, Massimo, Testa, Luca, Lefevre, Thierry, Guetta, Victor, Nissen, Henrik, Hernández, José-María, Roy, David, Teles, Rui C., Segev, Amit, Dumonteil, Nicolas, Fiorina, Claudia, Gotzmann, Michael, Tchetche, Didier, Abdel-Wahab, Mohamed, De Marco, Federico, Baumbach, Andreas, Laborde, Jean-Claude, Kornowski, Ran·2012·Circulation

Abstract

Background—: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. Methods and Results—: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. Conclusions—: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.112.104505

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

See all 583

Metadata

Authors
Dvir, D., Webb, J., Brecker, S., Bleiziffer, S., Hildick-Smith, D., Colombo, A., Descoutures, F., Hengstenberg, C., Moat, N. E., Bekeredjian, R., Napodano, M., Testa, L., Lefevre, T., Guetta, V., Nissen, H., Hernández, J.-M., Roy, D., Teles, R. C., Segev, A., Dumonteil, N., Fiorina, C., Gotzmann, M., Tchetche, D., Abdel-Wahab, M., De Marco, F., Baumbach, A., Laborde, J.-C., & Kornowski, R.
Venue
Circulation
Published
2012-11-06
Volume
126
Issue
19
Pages
2335-2344
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2158847848
Cited by
583
References
28
FWCI
32.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves: Results From the Global Valve-in-Valve Registry. https://app.cochat.ai/papers/10.1161/circulationaha.112.104505
The paper
Dvir, D., Webb, J., Brecker, S., Bleiziffer, S., Hildick-Smith, D., Colombo, A., Descoutures, F., Hengstenberg, C., Moat, N. E., Bekeredjian, R., Napodano, M., Testa, L., Lefevre, T., Guetta, V., Nissen, H., Hernández, J.-M., Roy, D., Teles, R. C., Segev, A., . . . Kornowski, R. (2012). Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves: Results From the Global Valve-in-Valve Registry. Circulation. https://doi.org/10.1161/circulationaha.112.104505

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.