Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record.

Fractional Flow Reserve–Guided Versus Angiography-Guided Coronary Artery Bypass Graft Surgery

Open access
Toth, Gabor, De Bruyne, Bernard, Casselman, Filip, De Vroey, Frederic, Pyxaras, Stylianos, Di Serafino, Luigi, Van Praet, Frank, Van Mieghem, Carlos, Stockman, Bernard, Wijns, William, Degrieck, Ivan, Barbato, Emanuele·2013·Circulation

Abstract

Background—: Fractional flow reserve (FFR) is well established for patients undergoing percutaneous coronary intervention, yet little is known about candidates for coronary artery bypass graft surgery. Methods and Results—: From 2006 to 2010, we retrospectively included in this registry 627 consecutive patients treated by coronary artery bypass graft surgery having at least 1 angiographically intermediate stenosis. In 429 patients, coronary artery bypass graft surgery was based solely on angiography (angiography-guided group). In 198 patients, at least 1 intermediate stenosis was grafted with an FFR ≤0.80 or deferred with an FFR >0.80 (FFR-guided group). The end point was major adverse cardiovascular events at 3 years, defined as the composite of overall death, myocardial infarction, and target vessel revascularization. The rate of angiographic multivessel disease was similar in the angiography-guided and FFR-guided groups (404 [94.2%] versus 186 [93.9%]; P =0.722). In the FFR-guided group, this was significantly downgraded after FFR measurements to 86.4% ( P <0.001 versus before FFR) and was associated with a smaller number of anastomoses (3 [2–3] versus 3 [2–4]; P <0.001) and rate of on-pump surgery (49% versus 69%; P <0.001). At 3 years, major adverse cardiovascular events were not different between the angiography-guided and FFR-guided groups (12% versus 11%; hazard ratio, 1.030; 95% confidence interval, 0.627–1.692; P =0.908). However, the FFR-guided group compared with the angiography-guided group presented a significantly lower rate of angina (Canadian Cardiovascular Society class II–IV, 31% versus 47%; P <0.001). Conclusions—: FFR-guided coronary artery bypass graft surgery was associated with a lower number of graft anastomoses and a lower rate of on-pump surgery compared with angiography-guided coronary artery bypass graft surgery. This did not result in a higher event rate during up to 36 months of follow-up and was associated with a lower rate of angina.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.002740

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Toth, G., De Bruyne, B., Casselman, F., De Vroey, F., Pyxaras, S., Di Serafino, L., Van Praet, F., Van Mieghem, C., Stockman, B., Wijns, W., Degrieck, I., & Barbato, E.
Venue
Circulation
Published
2013-09-24
Volume
128
Issue
13
Pages
1405-1411
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2116600535
Cited by
202
References
0
FWCI
18.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fractional Flow Reserve–Guided Versus Angiography-Guided Coronary Artery Bypass Graft Surgery. https://app.cochat.ai/papers/10.1161/circulationaha.113.002740
The paper
Toth, G., De Bruyne, B., Casselman, F., De Vroey, F., Pyxaras, S., Di Serafino, L., Van Praet, F., Van Mieghem, C., Stockman, B., Wijns, W., Degrieck, I., & Barbato, E. (2013). Fractional Flow Reserve–Guided Versus Angiography-Guided Coronary Artery Bypass Graft Surgery. Circulation. https://doi.org/10.1161/circulationaha.113.002740

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.