CoChat

Systemic Hypertension in Low-Gradient Severe Aortic Stenosis With Preserved Ejection Fraction

Eleid, Mackram F., Nishimura, Rick A., Sorajja, Paul, Borlaug, Barry A. · 2013 · Circulation
Cited by 121

The DOI matches its Crossref record.

Abstract

Background—: Low-gradient severe aortic stenosis with preserved ejection fraction is an increasingly recognized entity, and symptomatic patients may benefit from aortic valve replacement. However, systemic hypertension frequently coexists with low-gradient severe aortic stenosis, which itself may cause elevated left ventricular (LV) filling pressures with resultant symptoms of dyspnea. Methods and Results—: Symptomatic patients with hypertension (aortic systolic pressure >140 mm Hg) and low-gradient (mean gradient <40 mm Hg) severe aortic stenosis (aortic valve area <1 cm 2 ) with preserved ejection fraction (ejection fraction >50%) who underwent invasive hemodynamic catheterization of the left and right sides of the heart received infusion of intravenous sodium nitroprusside to reduce blood pressure and arterial afterload. At baseline, patients had severe hypertension (aortic systolic pressure, 176±26 mm Hg), pulmonary hypertension (mean pressure, 39±12 mm Hg), elevated LV end-diastolic pressure (19±5 mm Hg), and reduced stroke volume (33±8 mL/m 2 ). All measures of afterload were reduced with nitroprusside ( P <0.001 for all). Nitroprusside reduced mean pulmonary artery pressure (25±10 mm Hg) and LV end-diastolic pressure (11±5 mm Hg; P <0.001 for both compared with baseline). Aortic valve area (0.86±0.11 to 1.02±0.16 cm 2 ; P =0.001) and mean gradient (27±5 to 29±6 mm Hg; P =0.02) increased with nitroprusside. Conclusions—: Systemic hypertension in low-gradient severe aortic stenosis with preserved ejection fraction is associated with elevated LV filling pressures and pulmonary hypertension. Treatment of hypertension with vasodilator therapy results in a lowering of the total LV afterload, with a decrease in LV filling pressures and pulmonary artery pressures. These findings have important implications for the management of patients with low-gradient severe aortic stenosis with preserved ejection fraction and hypertension.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.113.003071

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 121

Metadata

Authors
Eleid, M. F., Nishimura, R. A., Sorajja, P., & Borlaug, B. A.
Venue
Circulation
Published
2013-09-17
Volume
128
Issue
12
Pages
1349-1353
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2115191535
Cited by
121
References
0
FWCI
6.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systemic Hypertension in Low-Gradient Severe Aortic Stenosis With Preserved Ejection Fraction. https://app.cochat.ai/papers/10.1161/circulationaha.113.003071
The paper
Eleid, M. F., Nishimura, R. A., Sorajja, P., & Borlaug, B. A. (2013). Systemic Hypertension in Low-Gradient Severe Aortic Stenosis With Preserved Ejection Fraction. Circulation. https://doi.org/10.1161/circulationaha.113.003071

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.