The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In-Hospital Complications Associated With Catheter Ablation of Atrial Fibrillation in the United States Between 2000 and 2010: Analysis of 93 801 Procedures
Open accessAbstract
Background—: Atrial fibrillation ablation has made tremendous progress with respect to innovation, efficacy, and safety. However, limited data exist regarding the burden and trends in adverse outcomes arising from this procedure. The aim of our study was to examine the frequency of adverse events attributable to atrial fibrillation (AF) ablation and the influence of operator and hospital volume on outcomes. Methods and Results—: With the use of the Nationwide Inpatient Sample, we identified AF patients treated with catheter ablation. We investigated common complications including cardiac perforation and tamponade, pneumothorax, stroke, transient ischemic attack, vascular access complications (hemorrhage/hematoma, vascular complications requiring surgical repair, and accidental arterial puncture), and in-hospital death described with AF ablation, and we defined these complications by using validated International Classification of Diseases, Ninth Revision, Clinical Modification diagnosis codes. An estimated 93 801 AF ablations were performed from 2000 to 2010. The overall frequency of complications was 6.29% with combined cardiac complications (2.54%) being the most frequent. Cardiac complications were followed by vascular complications (1.53%), respiratory complications (1.3%), and neurological complications (1.02%). The in-hospital mortality was 0.46%. Annual operator (<25 procedures) and hospital volume (<50 procedures) were significantly associated with adverse outcomes. There was a small (nonsignificant) rise in overall complication rates. Conclusions—: The overall complication rate was 6.29% in patients undergoing AF ablation. There was a significant association between operator and hospital volume and adverse outcomes. This suggests a need for future research into identifying the safety measures in AF ablations and instituting appropriate interventions to improve overall AF ablation outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852 · cited 4×
“2104 The past decade has seen catheter ablation of atrial fibril-lation (AF) transition from a new unproven procedure to a commonly performed procedure in most major medical centers throughout the world.1 Catheter ablation of AF has also evolved into a mainstay of therapy for patients with drugrefractory symptomatic A…”
BackgroundResultInfluential
Cited by
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001193 · Cited by 2,765
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial Fibrillation
Joglar, J. A., Chung, M. K., Armbruster, A. L., Benjamin, E. J., Chyou, J. Y., Cronin, E. M., Deswal, A., Eckhardt, L. L., Goldberger, Z. D., Gopinathannair, R., et al. (2024) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.08.017 · Cited by 933
Self-citationVerma, A., Cairns, J. A., Mitchell, L. B., Macle, L., Stiell, I. G., Gladstone, D., McMurtry, M. S., Connolly, S., Cox, J. L., Dorian, P., et al. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.08.001 · Cited by 477
Metadata
- Authors
- Deshmukh, A., Patel, N. J., Pant, S., Shah, N., Chothani, A., Mehta, K., Grover, P., Singh, V., Vallurupalli, S., Savani, G. T., Badheka, A., Tuliani, T., Dabhadkar, K., Dibu, G., Reddy, Y. M., Sewani, A., Kowalski, M., Mitrani, R., Paydak, H., & Viles-Gonzalez, J. F.
- Venue
- Circulation
- Published
- 2013-11-05
- Volume
- 128
- Issue
- 19
- Pages
- 2104-2112
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1987903002
- Cited by
- 581
- References
- 1
- FWCI
- 36.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In-Hospital Complications Associated With Catheter Ablation of Atrial Fibrillation in the United States Between 2000 and 2010: Analysis of 93 801 Procedures. https://app.cochat.ai/papers/10.1161/circulationaha.113.003862
- The paper
- Deshmukh, A., Patel, N. J., Pant, S., Shah, N., Chothani, A., Mehta, K., Grover, P., Singh, V., Vallurupalli, S., Savani, G. T., Badheka, A., Tuliani, T., Dabhadkar, K., Dibu, G., Reddy, Y. M., Sewani, A., Kowalski, M., Mitrani, R., Paydak, H., & Viles-Gonzalez, J. F. (2013). In-Hospital Complications Associated With Catheter Ablation of Atrial Fibrillation in the United States Between 2000 and 2010: Analysis of 93 801 Procedures. Circulation. https://doi.org/10.1161/circulationaha.113.003862
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.