CoChat

Noninvasive Imaging of Early Venous Thrombosis by 19 F Magnetic Resonance Imaging With Targeted Perfluorocarbon Nanoemulsions

Open access
Temme, Sebastian, Grapentin, Christoph, Quast, Christine, Jacoby, Christoph, Grandoch, Maria, Ding, Zhaoping, Owenier, Christoph, Mayenfels, Friederike, Fischer, Jens W., Schubert, Rolf, Schrader, Jürgen, Flögel, Ulrich · 2015 · Circulation
Cited by 95

The DOI matches its Crossref record.

Abstract

Background—: Noninvasive detection of deep venous thrombi and subsequent pulmonary thromboembolism is a serious medical challenge, since both incidences are difficult to identify by conventional ultrasound techniques. Methods and Results—: Here, we report a novel technique for the sensitive and specific identification of developing thrombi using background-free 19 F magnetic resonance imaging, together with α2-antiplasmin peptide (α2 AP )–targeted perfluorocarbon nanoemulsions (PFCs) as contrast agent, which is cross-linked to fibrin by active factor XIII. Ligand functionality was ensured by mild coupling conditions using the sterol-based postinsertion technique. Developing thrombi with a diameter <0.8 mm could be visualized unequivocally in the murine inferior vena cava as hot spots in vivo by simultaneous acquisition of anatomic matching 1 H and 19 F magnetic resonance images at 9.4 T with both excellent signal-to-noise and contrast-to-noise ratios (71±22 and 17±5, respectively). Furthermore, α2 AP -PFCs could be successfully applied for the diagnosis of experimentally induced pulmonary thromboembolism. In line with the reported half-life of factor XIIIa, application of α2 AP -PFCs >60 minutes after thrombus induction no longer resulted in detectable 19 F magnetic resonance imaging signals. Corresponding results were obtained in ex vivo generated human clots. Thus, α2 AP -PFCs can visualize freshly developed thrombi that might still be susceptible to pharmacological intervention. Conclusions—: Our results demonstrate that 1 H/ 19 F magnetic resonance imaging, together with α2 AP -PFCs, is a sensitive, noninvasive technique for the diagnosis of acute deep venous thrombi and pulmonary thromboemboli. Furthermore, ligand coupling by the sterol-based postinsertion technique represents a unique platform for the specific targeting of PFCs for in vivo 19 F magnetic resonance imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.114.010962

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Temme, S., Grapentin, C., Quast, C., Jacoby, C., Grandoch, M., Ding, Z., Owenier, C., Mayenfels, F., Fischer, J. W., Schubert, R., Schrader, J., & Flögel, U.
Venue
Circulation
Published
2015-04-21
Volume
131
Issue
16
Pages
1405-1414
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2094848633
Cited by
95
References
0
FWCI
7.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Imaging of Early Venous Thrombosis by 19 F Magnetic Resonance Imaging With Targeted Perfluorocarbon Nanoemulsions. https://app.cochat.ai/papers/10.1161/circulationaha.114.010962
The paper
Temme, S., Grapentin, C., Quast, C., Jacoby, C., Grandoch, M., Ding, Z., Owenier, C., Mayenfels, F., Fischer, J. W., Schubert, R., Schrader, J., & Flögel, U. (2015). Noninvasive Imaging of Early Venous Thrombosis by 19 F Magnetic Resonance Imaging With Targeted Perfluorocarbon Nanoemulsions. Circulation. https://doi.org/10.1161/circulationaha.114.010962

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.