CoChat

Temporal Trends in Percutaneous Coronary Intervention Appropriateness: Insights From the Clinical Outcomes Assessment Program

Bradley, Steven M., Bohn, Chad M., Malenka, David J., Graham, Michelle M., Bryson, Chris L., McCabe, James M., Curtis, Jeptha P., Lambert-Kerzner, Anne, Maynard, Charles · 2015 · Circulation
Cited by 68

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Background—: It is unknown whether the appropriate use of percutaneous coronary intervention (PCI) has improved over time and whether trends in PCI appropriateness have been accompanied by changes in the use of PCI. Methods and Results—: We applied appropriate use criteria to determine the appropriateness of all 51 872 PCI performed in Washington State from 2010 through 2013. We evaluated the number of PCIs performed from 2006 through 2013 to provide a comparator period that preceded statewide appropriateness assessment beginning in 2010. Between 2010 and 2013, the overall number of PCI decreased by 6.8% (13 267 PCIs in 2010 to 12 193 in 2013) with a 43% decline in the number of PCIs for elective indications (3818 PCIs in 2010 to 2193 PCIs in 2013). The decline in the use of elective PCI was significantly larger after the onset of statewide PCI appropriateness assessment in 2010 ( P =0.03). The proportion of elective PCIs classified as appropriate increased from 26% in 2010 to 38% in 2013, whereas the proportion of inappropriate PCIs decreased from 16% to 13% ( P <0.001 for trends). Significant improvements in the proportion of inappropriate PCI were limited to the tertile of hospitals with the largest decline in PCIs classified as inappropriate (25% in 2010 to 12% in 2013; P =0.03). Conclusions—: In Washington State, the use of PCI for elective indications has decreased over time with concurrent improvements in PCI appropriateness. However, improvements in PCI appropriateness were limited to a minority of hospitals. Understanding processes at these high-performing hospitals may inform efforts to improve PCI appropriateness.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.114.015156

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 68

Metadata

Authors
Bradley, S. M., Bohn, C. M., Malenka, D. J., Graham, M. M., Bryson, C. L., McCabe, J. M., Curtis, J. P., Lambert-Kerzner, A., & Maynard, C.
Venue
Circulation
Published
2015-07-07
Volume
132
Issue
1
Pages
20-26
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1480079961
Cited by
68
References
1
FWCI
7.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temporal Trends in Percutaneous Coronary Intervention Appropriateness: Insights From the Clinical Outcomes Assessment Program. https://app.cochat.ai/papers/10.1161/circulationaha.114.015156
The paper
Bradley, S. M., Bohn, C. M., Malenka, D. J., Graham, M. M., Bryson, C. L., McCabe, J. M., Curtis, J. P., Lambert-Kerzner, A., & Maynard, C. (2015). Temporal Trends in Percutaneous Coronary Intervention Appropriateness: Insights From the Clinical Outcomes Assessment Program. Circulation. https://doi.org/10.1161/circulationaha.114.015156

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.